Minimum hydraulic quantity
7 quarts in both L and R systems
Minimum oil quantity
9 quarts: MX station
7 quarts: non-MX station
Max brake temp prior to takeoff?
115 C. (up to 2200’ MSL).
Minimum taxiway width for 180 degree turn?
81’
MTW
122,000#
MTOW
121,000#
MLW
110,000#
MZFW
100,500#
Maximum lateral fuel imbalance
1,500#
Speedbrakes must be stowed with flaps BEYOND?
20 degrees
What temperature might require use of engine anti-ice on the ground?
6 C
With visible moisture or 3 C temp/dewpoint spread or wet taxiways, etc.
How is an engine run-up accomplished?
Run the engines to 40% N1 for 10 seconds every 60 minutes.
How is a standing takeoff accomplished?
Complete a standing takeoff during icing conditions. Run the engines to 50% N1 before releasing brakes.
What is the rated thrust of the BR715?
21K
What are the starter duty limits?
3 starts, 3 minutes each. 15 seconds between each start. 15 minutes cooling after that.
What are the APU starter duty limits?
3 consecutive starts, followed by 30 minutes cooling
How much fuel can each tank carry and what is the total tank capacity?
9300 wing tanks
6000 center tank
24,600 total
What is the seating capacity/ configuration?
110
12/98
Wingspan
93 feet
Which system powers the rudder?
Right
Which system powers the landing gear?
Right
If right hydraulic system fails (or you pull the emergency gear extension handle) which way can you turn normally?
Right
Minimum pneumatic pressure prior to engine start
32 psi
Motor engine on manual starts. How long and at what rpm?
30 seconds above 19 percent N2