Systems Flashcards
Eng fire protection and powered how?
ENG ovht/fire det - battery bus
Eng fire ext - HOT BAT BUS
ENG OVHT/FIRE DETECTION
each engine - 2 loops
Lower limit - OVHT
Higher limit - FIRE
BOth loop must sense condition
Remains - temp drop
Fault monitoring circuit?
one loop fails with OVHT DET switch in NORMAL, that loop = auto deselected - remaining loop function as single loop.
FD indication of single loop failure?
NO
Both loops fail on engine - FAULT light on and system inop.
Only Loop A or B selected?
Single loop system
Non selected loop - not monitored
Selected loop fails - FAULT light
APU fire protection?
fire detection - battery bus
fire extinguishing - hot batt bus
Detection?
singe loop
Fault monitoring system
loop fails, the APU DET INOP light illuminates -
Main wheel well fire detection powered?
AC TRANSFER BUS 2 and BATT bus
single loop
Cargo compartment smoke detection?
DC Bus 1 and DC Bus 2
Cargo fire suppression?
HOT BAT BUS
Total loop cargo compartment?
dual loop
How many needs to detect smoke?
both
Detector failure?
Sys manually converted to single loop with DETECT SELECT switch.
Power failure of one loop?
Auto converts to single loop