Switchboard Groups

A

SG - Generator
SA - Stbd side
SB - Port Side
SP - Shore Power

10 Total Switchboards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

APD

A

SWBD Automatic Paralleling Device
Utilized for the main bus breakers to parallel two generators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Positions of the APD

A

OFF, PERMISSIVE, RUN and TEST

PERMISSIVE (PERM): Phase (+/- 15 electrical degrees), freq. (+/- 0.2 Hz), Voltage (+/- 5%); breakers will be allowed to close by operator

RUN: Adjusts oncoming generator voltage and frequency to match bus conditions, and close designated breaker automatically

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Load Shed

A

Feature in the Distribution System to prevent overload
- Can be initiated by the Commercial Off The Shelf Multifunction Monitor (COTS MFM) or by watchstanders at the UCCs or SWBDs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Load Shed

2 Stages of Load Shed

A
  1. LS1 - 100% of rated load for 100ms
  2. LS2 - 100% of rated load for additional 5 seconds, after LS1
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Switchboards

Switchboards associated with #1 GTG

A

1SG, 1SA, 1SB (Aux 1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Switchboards

Switchboards associated with #2 GTG

A

2SG, 2SA, 2SB (Main 2)
2SP (Shore Power)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Switchboards

Switchboards associated with #3 GTG

A

3SG, 3SA, 3SB (3 Gen)

How well did you know this?