Strategic and Tactical Flashcards
The stage of fire when the oxygen or fuel starts to diminish is called: _________ 6
Decay Stage
The action required when a backdraft situation is recognized is to? 9
Provide adequate ventilation above the fire
T. F. Pre-incident planing is a method of gathering facts about a building, or a process within a building. 12
True
T. F. Pe-incident planing lets a fire department evaluate conditions and situation in its area of responsibility prior to an emergency. 12
True
T. F. Historical data enables a fire department to select the most critical properties or specific problems in our community that should be pre-planned. 13
True
T. F. Pre-planing data should assist a fire department in analyzing potential problems and developing a plan of action based upon what may occur. 13
True
T. F. Responders should review and update pre-plan information during site visits. 14
True
T. F. The scheduling of multiple dates for site visitation so all fire department members can visit special pre-planned sites is not necessary since the data should be incorporated into company drills to permit a constant refreshment for all members. 14
False
T. F. Wire-glass windows may crack from radiant heat. 14
True
T. F. Smoke proof doors and smoke removal systems can assist in minimizing evacuation problems. 14
True
T. F. Resource utilization includes securing the services of outside agencies, such as the police, red cross, private security companies, public works, public health, utilities, or federal, state, or local agencies. 15
True
T. F. Outside agencies should not be used for evacuation purposes at incidents attended by the fire department. 15
False
Implementation of a pre-plan during a simulated exercise can be used to adjust the pre-plan. It is beneficial to know: 16
What problems the fire department encountered.
If the community was involved in the exercise , where there any problems?
Did the plan or facilities find any discrepancies in the plan?
According to the National Fire Academy’s fire flow formula, for a fire involving 25% of the first floor of a 3-story building that is 30 feet by 40 feet with exterior exposures on two sides the fire floor would be? 17-19
200 gallons per minute
Accordingly to the National Fire Academy’s fire flow formula, if an exterior exposure becomes involved in fire what amount of fire flow should be added to the original fire flow? 18
25% of the actual required fire flow fro the building on fire should be added to provide protection for each side of a building that has exterior exposures.