Steam Flashcards

You may prefer our related Brainscape-certified flashcards:
1
Q

Steam pressures in generating plants can be as high as _ psi with temperatures reaching _ degrees Fahrenheit.

a. 170 psi, 900 degrees
b. 170 psi, 350 degrees
c. 2000 psi, 900 degrees

A

C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The only time we enter a Con Ed generating plant without Con Ed personnel is when we have a confirmed life hazard that needs to be addressed.

a. Disagree
b. Agree

A

Disagree

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If a vent pipe has a _ stripe over the top of it, this indicates that the steam is a result of a water leak, NOT a leaking steam main.

a. Black
b. Red
c. Green
d. Blue

A

D Blue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In an emergency at a HELB inside a building, FD members may shut which valve?

a. Outside Steam Shutoff Valve
b. Inside Service Valve
c. Curb Valve
d. Head of Service Valve

A

B Inside Service Shutoff Valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Signal transmitted due to the probable presence of asbestos at the scene?

a. 10-87
b. 10-80
c. 10-66
d. 10-86

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Steam incident is incorrect?

a. Limit number of FFs exposed to probable asbestos contamination
b. Est the SA where units will not become contaminated by asbestos and where communications are effective.
c. Consider shutting the HVAC systems of nearby buildings
d. Approach an outdoor HELB from downwind and stay clear of the vapor plume

A

D

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

High Energy Line Break incorrect
A. Have operating units shut down Inside Service Valve which be labeled and sealed
B. If unable to locate a shutoff inside of bldg, have bldg steam shutoff that is located outside of bldg shut by Ladder company
C. Notify Con Ed of any valves that are shut
D. No steam valves shall be reopened once they are shut

A

B FD members should not attempt to shut valves outside of bldg. This valve should only be shut by Con Ed steam personnel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Steam incorrect
A: Con Ed is the only company that generates and provides high pressure steam in NYC.
B: Steam pressures in generating plants can be as high as 2,000 psi with temperatures reaching 900ºF.
C: Steam pressures in buried supply piping and in supplied buildings can be as high as 170 psi and temps as high as 350ºF.
D: Asbestos pipe insulation can be found in the plant, on pipes buried under the street and in buildings supplied with steam.

A

Con Ed is not the only entity generating Hi Pr steam in NYC. High pressure steam, generated for use in housing complexes, hospitals and various commercial locations, can be found in any borough. These District Steam systems will have the same hazards as the Con Ed system but will not be run or maintained by the Con Ed. When discovered, district steam systems shall be entered into the CIDS Program

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

HELB incorrect
A: Only enter a Con Ed Steam Generating Plant without Con Ed personnel when there is a life hazard.
B: Con Ed White Hat can remain at the Command Post as a Technical Specialist.
C: Plant personnel will mitigate the emergency. FDNY should only enter the plant to perform search and rescue for missing plant personnel.
D: Contact the Con Ed White Hat who can provide critical info and an escort if entry is necessary, as well as provide a personnel accountability report to see if anyone is missing

A

Never enter a Con Edison generating plant without Con Ed personnel. Instead, respond to the designated mustering site outside the plant.
Steam 4.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

(HELB) at a Con Ed generating plant incorrect
A: Plant personnel will mitigate the emergency.
B: Enter the generating plant to perform search and rescue for missing plant personal only after a con ed escort is provided.
C: Recognize this is not a haz-mat incident because there will not be asbestos in a steam generating plant.
D: Contact the Con Edison White Hat.

A

C Emergency Procedures - Steam sec 4.1, 4.2
C. Asbestos pipe insulation can be found in the plant, on pipes buried under the street and in buildings supplied with steam.

B. When entering the plant, stay close to the provided escort and be guided by their advice.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Steam and HELB correct (2)

  1. Underground steam pipes are most commonly wrapped in asbestos insulation and a HELB will likely result in an asbestos release that spreads over a large area.
  2. Asbestos remains in most Con Edison steam manholes.
  3. Asbestos has been removed from most underground piping.
  4. Escaping high pressure steam can hurl debris at a maximum of 150 mph. Anyone in the vicinity of the break is in danger of being struck by flying, high velocity debris.
  5. The noise of escaping steam will make radio and verbal communication ineffective in the immediate vicinity of the release.
A

1, 5
2. Asbestos has been removed from Con Ed steam manholes.
3. Asbestos remains on most of the underground piping.
4. Escaping high pressure steam can hurl debris at 200 mph.
EP Steam 4.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

HELB incorrect
A: Do not randomly shut steam valves inside of a supplied building.
B: Once a steam valve is shut, do not reopen it and notify Con Edison.
C: In an emergency, members may shut the Inside Service Valve which will be labeled and sealed.
D: The building steam shutoff valve should be shut by Con Edison steam personnel or FD members under the supervision of a chief and in consultation with Con Ed white hat.

A

D There is a building steam shutoff located outside the building. FD members should not attempt to shut this valve. This valve should only be shut by Con Ed steam personnel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

10-60 transmitted for a ruptured steam main that could be a terrorist attack. Incorrect
A: Probable presence of asbestos makes this a haz-mat incident until proven otherwise by sampling/ testing
B: All responding units must report to the Staging Area, regardless of alarm level or assignment.
C: Responding units shall monitor radiation detection devices upon receipt of an alarm for a ruptured steam main.
D: Implement a command channel early and consider utilization of the Interoperability and FDNY/NYPD TAC “U” ch.13, Post Radios and/or the 800Mz radios.

A

B. All responding units must report to the ICP in an area that is safe from flying debris and is far enough away from the noise of the burst main to allow voice communications.
Personnel accountability is essential and all responding units and Chief Officers must report into the ICP.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly