#StatCheck Flashcards
What level of accuracy are powders measured to?
1 mg; e.g. 0.422g or 422mg
What level of accuracy are volumes measured to?
1 decimal place; e.g. 10.5mL
What is the nominal pore size specified in the B.P. for sterilisation via filtration?
0.22μm or less (micrometres)
How many particles are dispersed per minute from rapid mobility (e.g. walking/climbing stairs)?
10,000,000 (LOADS)
How far does a sneeze travel compared with saliva during coughing and normal talking?
Sneeze: 10-15 feet
Coughing: 4-6 feet
Normal talking: 2-3 feet
What is the test dose for Ambisome IV Infusion?
- 1 mg over 10 minutes
- Patient observed for 30 minutes
What is the minimum in-line filter membrane pore diameter for AmBisome?
- 1.0 μm
- Don’t want to filter out drug
What is the shelf-life of Ambisome after reconstitution?
Up to 7 days when stored at 2-8 Degrees Celsius.
How often should an operator complete and pass a BTT to continue manufacturing sterile products?
Every 3 to 6 months.
How long is a settle plate incubated for in a BTT and at what temperature?
- 24 hours
- At 37 Degrees Celsius (mimic body’s environment)
What is the minimum number of items to be tested as part of a batch of more than 200 containers, as part of quality assurance?
10 containers
What is the minimum number of items to be tested as part of a batch of less than 200 containers, as part of quality assurance?
- 5%
- Or 2 containers
(whichever is greater)
As part of sterility testing (quality control), what is the maximum filter pore size sized to pass a sample through? (to retain particles/micro-organisms)
0.45 μm or less.