1
Q

What are the steps for a normal engine start?

A

When the ENG START switch light is pressed, the:

  • ISOL valve opens
  • both engine bleed SOVs open
  • associated start valve opens
  • air turbine starter ATS engages
  • both PACK valves close.

When the starter cut out occurs:
all valves return to their previously selected position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

During normal engine starts, what kind of protection does FADEC provide?

A

Hot and hung starts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

During a normal engine start, the starter should cut out at?

If it does not?

A

50% N2

Turn off manually

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Or a normal engine start, what is the starter limitation for attempts 1–2?

3–5?

A

90 seconds on 10 seconds off (1-2)

90 seconds on 5 minutes off (3-5)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the EPC for a HOT START?

A

Idle cut off
motor until 120°C ITT
90 second limit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the top altitude at which we can start an engine?

A

FL 210 top altitude for windmill start

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When are we required to select the CONT IGNITION?

When does it come on automatically?

A

Contaminated runways
moderate/severe turbulence moderate/severe rain and particulates.
Thunderstorms

Stick shaker, high angle of attack, stall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly