Thermal Performance
1. Precondition or Optimization
2. Intent
3. Issue
4. Solutions
- Precondition
- Provide thermal environment most users find acceptable
- The thermal environment is ranked as one of the strongest contributing factors to overall health and satisfaction. Thermal temperatures can also impact comfort and productivity.
- Provide a space that meets the six core parameters: air
temperature, humidity, air movement, mean radiant temperature of surrounding surfaces, metabolic rate and clothing
insulation
Verify Thermal Comforts
1. Precondition or Optimization
2. Intent
3. Issue
4. Solutions
- Optimization
- Enhance thermal comfort by ensuring that at least 80% of users are satisfied with the their thermal environment.
- Despite having established standards, studies show that only 11% meet thermal environments that meet general human satisfaction.
- Survey for thermal comfort. For spaces over 45 occupants, at least 35% need to answer. Scores need to be at least 80% satisfactory.
Thermal Zoning
1. Precondition or Optimization
2. Intent
3. Issue
4. Solutions
- Optimization
- Enhancing thermal comfort through zoning
- thermal comfort preferences are highly invidivdual. Allowing digital thermostats can help individuals meet thier needs.
- Control of each thermal zone is each thermal zone is 650 ft²(60 m²) or 10 occupants, whichever is larger.
Individual Thermal Control
1. Precondition or Optimization
2. Intent
3. Issue
4. Solutions
- Optimization
- Maximize and personalize thermal comfort among all individuals
- Due to individualized nature of thermal comfort, not everyone will be equally comfortable under the same same conditions. Secondary factors such as age, sex, health conditions also play role.
- Provide personal cooling and heating options like a desk fan, electric heater, cooling/heating chair without affecting other occupants. Allowing a flexible dress code can also assist.
Radiant Thermal Comfort
1. Precondition or Optimization
2. Intent
3. Issue
4. Solutions
- Optimization
- improve ventilation and thermal comfort by incorporating radiant heat and cooling into building designs.
- All air systems can be disrupted by windows, uninsulated walls, and have a higher risk of draft discomfort due to elevated velocity.
- Implementing radiant heat and cooling strategies provide heat and cooling to surrounding areas such as floor, walls, and ceilings. This system is more efficient and quiet.
Provide examples of loud zones
Rooms or areas where loud activities occur such as equipment rooms, fitness rooms, or appliance rooms
Provide examples of mixed zones
presentation rooms, collaboration rooms, open conferencing spaces
What is a circulation zone
areas that are intended for egress between regularly occupied spaces
What is reverberation time
The amount of time that an impulse (balloon popping), or an interrupted noise requires to decrease by 60 decibel
Define LEQ
Sound pressure level metric that is equivalent to the acoustic energy measured over the duration of a specific sound pressure level
What is a sound transmission class (STC)?
Number rating of the acoustical performance across a partitions as measured in a laboratory.
What is a noise isolation class (NTC)?
measurement of sound insulation across a partition dividing two spaces.
Sound Mapping
1. Precondition or Optimization
2. Intent
3. Issue
4. Solutions
- Precondition
- Incorporate strategies prevent acoustic disturbances from various sources.
- Architectural trends such as open workspaces, exposed HVAC foster noisy environments. When noise volume increases, it leads to less productivity.
- Provide an annotated floor plan that shows zones such as loud, quiet, mixed.
Maximum Noise Level
1. Precondition or Optimization
2. Intent
3. Issue
4. Solutions
- Optimization
- Achieve desired ambient noise levels such that HVAC, exterior noise intrusion or other noise sources do not
impact occupant health and well-being. - when background noises such as HVAC systems, traffic, or other building services are noisy, it decreases productivity and interrupt performance.
- Background noise levels are measured over a period of five minutes and average sound pressure levels do not
exceed the thresholds
What are the preconditions of Thermal and sound ?
- Thermal performance
- Sound mapping