SOP Flashcards
Personal accountability reports (PARs) will be called and recorded on the command board at these benchmarks. 
- Change of strategy
- Code Red Called
- Report of a lost or injured fire fighter.
- Building collapse
- 20 minute intervals.
- Fire declared under control/out 
The _________ must control access to, within, and from the emergency incident, so that the assigned location of each division, company, staff and support personnel can always be identified. 
Incident Commander
 The _______ shall assist as a point of entry control. 
Safety Officer
On our second alarm or greater structural fires, tactical work boards shall be prepared for a transition to a “_________ ____ __________”level of control 
Point of Entry
The Richardson fire department shall implement the use of passports on all_______.
Second alarm or greater structural fires, or whenever the incident commander deems it necessary. 
The Roll Call reports should begin with___.. 
Higher risk assignments, and then proceed to the lower risk assignments
At least_____________ for each rescuer should be on standby outside the entry points 
2 fully equipped firefighters
Tone sent from dispatch designated as the audible warning notification for firefighters to immediately begin withdrawal of the structure or hazard zone, as announced by the IC
Emergency Withdrawal
How long is the emergency withdrawal tone sounded? 
10 Seconds
Who is our fire department safety officer? 
Assistant Chief of Operations
Who is our fire department safety officer?
Assistant, chief of operations. 
Who is responsible for the management of the wellness program? 
The fire department, safety officer 
Who is responsible for the health and safety of all personnel on the scene of an incident? 
The Incident, Safety Officer 
Standard for fire department, safety officer, professional qualifications 
NFPA 1521
Standard for fire officer, professional qualifications
NFPA 1021
The incident commander shall assign the incident, safety officer whenever ……
The incident, size or scope exceeds their ability to reasonably satisfy this function themselves, or whenever they otherwise deem it appropriate 
The initial ISO can be
Any member of the fire department sworn service available to assist command in this role. 
Once adequate personnel are on scene, the initial ISO should be replaced by 
A promoted member of sworn service, who has the TCFP safety officer certification.
…….Promoted…..
Who do assistant safety officers report to in the incident chain of command?
ISO
High pressure hose 
Service test pressure of 300 psi or greater 
Standpipe Valve
Hose appliance with pressure gauge and slow close valve
Standpipe load
Attack line with a 2” minimum diameter and 2 1/2” couplings, and a smooth bore nozzle, attached 
Supply pumper
Engine positioned at the hydrant, pumping to the attack pumper
In higher pressure supply situation, those were the expected engine discharge pressure will exceed ______ the officer in charge should strongly consider utilizing a ______
200psi
Supply Pumper Positioned at the Hydrant
The supply pumper should pump to the attack pump or with an engine discharge pressure of 
150 PSI
On working high rise fires once a second chief officer arrived on scene, one of the chief officers, should report to the suppression floors and assume the role of __________ to manage our suppression and rescue activities within the structure. 
Operations
Elevators will not be utilized for incidents below the 
5th floor
Elevators may be utilized for incidents on or above the ______floor if deemed safe by the IC and shall be stopped at least ______below the reported fire floor. 
5th Floor
2 Floors
Commercial high-rise response
First engine company officer assumes 
Command
Commercial high-rise response
First engine company the driver assumes 
Lobby control
Commercial high-rise response
The second engine company officer is designated as
 division leader on the fire floor 
Commercial High Rise response 
Tactical objectives, the division leader shall accomplish 
Rescue
Fire Control
Property Conservation
Commercial high-rise response
The third engine company should 
Establish water supply 
Residential high rise response 
The first engine company officer 
Assumes Command
Residential high rise response 
First engine company, driver engineer assumes
Access control, preparing to route subsequent crews to the correct stairwell and or standpipe 
Residential high-rise response
The second engine company should
Establish water supply
Residential high-rise response
 The third engine company should
Coordinate with access control to identify the best entry point, stairwell, and or standpipe location in order to affect a quick fire attack.
The officer is designated as the division leader on the fire floor 
High rise parking garage response

First engine officer assumes
Command 
High rise parking garage response
Second engine
Establish water supply
High Rise Response
IAP pre-assignments for 2 alarm response
IC shall establish a staging officer, and or base manager and location 
Call second alarm RFD and Mutual aid resources will report to base if designated or staging 
Where is the safe refuge area in high-rise operations? 
3 floors below the fire floor
The in-line educators in service on RFD Apparatus, are rated at
125 GPM
The hose line between the educator, and the nozzle must not exceed 
150 feet
The educator Inlet pressure should be set to
200psi
There will be a delay of _______ before foam solution is discharged at the nozzle
12-15 seconds
Tilting the PPV fan back about to achieve proper coverage of the opening will enhance the overall operation 
20-30 degrees
The exhaust opening should be as close to the seat of fire as possible, and should be at least _____ and no more than ________ of the entrance opening 
75%
110%
After positive pressure ventilation has been established personnel entering the building should do so ______
Only through the entrance opening 
When using a single PPV fan on a standard door opening the fan should be placed approximately ______ from the door opening 
6 feet
Multiple PPV fan placement
Two PPV fans placed in series will achieve maximum effectiveness
Place one fan about 2 feet from the door opening and the second directly behind the first. About 5 to 6 feet from the door opening.
On large openings two or more PPV fans utilized 
Side by side will achieve maximum effectiveness
An intentional or malicious act to activate an alarm or affect a response by the fire department, knowing no emergency exists
False Alarm
An alarm activated for no emergency reason caused by a problem in the system, may be shown as a system
 System malfunction 
An alarm activated by an incorrect code, accidental, activation, or other products, such as painting, or dusting
Unintentional activation
A system activated because the person thought a true emergency existed 
Good intent call
All automatic fire, alarms dispatched, shall receive a response. In instances where the alarm company attempts to cancel, they responding unit may clear if none of the following are present.
The alarm is a water flow alarm
The alarm is from an activated, pull Station
The alarm is a re-occurring automatic alarm at the same address within a 24 hour period.
The alarm is at a multi family complex, and assisted-living or nursing facility
The alarm is a school during normal school hours 
Response to automatic alarms shall be
Code 3