Which form of BC/DR testing has the most impact on operations?
A. Tabletop
B. Dry run
C. Full test
D. Structured walk through
C. Full test
Explanation:
The full test will involve every asset in the organization including all personnel. The others will have less impact on the organization because they do not involve actually activating the plan
Which form of BC/DR testing has the least impact on operations?
A. Tabletop
B. Dry Run
C. Full Test
D. Structured Test
A. Tabletop
Explanation:
The tabletop test involves only essential personnel and none of the production assets.
Which characteristic of liquid propane increases its desirability as a fuel for backup generators?
A. Burn rate
B. Price
C. Does not spoil
D. Flavor
C. Does not spoil
Explanation:
Liquid propane does not spoil, which obviates the need to continually refresh and restock it and might make it more cost effective
How often should the CMB meet?
A. Whenever regulation dictate
B. Often enough to address organizational needs and reduce frustration with delay
C. Every week
D. Annually
B. Often enough to address organizational needs and reduce frustration with delay
Explanation:
Frustrated employees and managers can increase risk to the organization by implementing their own, unapproved modification to the environment
Adhering to ASHRAE standards for humidity can reduce the possibility of _____
A. Breach
B. Static Discharge
C. Theft
D. Inversion
B. Static Discharge
Explanation:
A data center with less than optimum humidity can have a higher static electricity discharge rate. Humidity has no bearing on breaches or theft, and inversion is a nonsense term used as a distractor
A UPS should have enough power to last how long?
A. 12 hours
B. 10 minutes
C. One day
D. Long enough for graceful shutdown
D. Long enough for graceful shutdown
Explanation:
The UPS is intended to last only long enough to save production data currently being processed. The exact quantity of time will depend on many variables and will differ from one data center to the next
A generator transfer switch should bring backup power online within what time frame?
A. 10 seconds
B. Before the recovery point objective is reached
C. Before the UPS duration is exceeded
D. Three days
C. Before the UPS duration is exceeded
Explanation:
generator power should be online before battery backups fail. The specific amount of time will vary between data centers
Which characteristic of automated patching makes it attractive?
A. Cost
B. Speed
C. Noise reduction
D. Capability to recognize problems and quickly
B. Speed
Explanation:
Automated patching is much faster and more efficient than manual patching. it is however not necessarily any less expensive than manual patching. Manual patching is overseen by administrators, who will recognize problems faster than automated tools. Noise reduction is not a factor in patch management at all
Which tool can reduce confusion and misunderstanding during a BC/DR response?
A. Flashlight
B. Controls matrix
C. Checklist
D. Call tree
C. Checklist
Explanation:
Checklists server as a reliable
When deciding whether to apply specific updates, it is best to follow ______ in order to demonstrate due care
A. Regulations
B. Vendor guidance
C. Internal policy
D. Competitors action
B. Vendor guidance
Explanation:
A data center that doesnt followe vendor guidance might be seen as failing to provide due care. Regulations, internal policy, and the actions of competitors might all inform the decision to perform an update and patch, but these dont necessarily bear directly on due care
The CMD should include representations from all of the following offices except ________
A. Regulators
B. IT Department
C. Security office
D. Management
A. Regulators
Explanation:
Regulators are not involved in an organizations CMB. The IT department, security office and management all play a role in the CMB process
For performance purposes, OS monitoring should include all of the following except _______
A. Disk space
B. Disk IO usage
C. CPU usage
D. Print spooling
D. Print spooling
Explanation:
Disk space, disk IO usage, and CPU usage are all standard performance monitoring metrics. Print spooling is not normally incorporated into performance monitoring plans
Maintenance mode requires all of these actions except ______
A. Remove all active production instances
B. Initiate enhanced security controls
C. Prevent new logins
D. Ensure logging continues
B. Initiate enhanced security controls
Explanation:
During maintenance mode, teams should remove all active production instances, prevent new logons and ensure that logging continues. There is not normally a need to initiate enhanced security controls
What is one of the reasons a baseline might be changed?
A. Numerous change requests
B. Power fluctuation
C. To reduce latency
D. Natural disaster
A. Numerous change requests
Explanation:
If the CMb is receving numerous change requests to the point where the number of requests would drop by modifying the baseline, then that is a good reason to change the baseline. The baseline should not be changed due to power fluctuations, to reduce redundancy or due to a natural disaster
In addition to battery backup, a UPS can offer which capability?
A. Communication redundancy
B. Line conditioning
C. Breach alert
D. Confidentiality
B. Line conditioning
Explanation:
A UPS can provide line conditioning, adjusting power so that it is optimized for the devices it serves and smoothing any power fluctuations. It does not provide confidetniality, breach alerts or communication redundancy