SI joint Flashcards
Rollins VCOT 2019
open reduction vs fluoro guided lag screws
fluoro guided more optimal screw placement and lower screw loosening rate
similar complication rates
Hanlon VS 2022
1 long lag, 2 short lag, 2 position screws
2 short screws strong stiffer vs 1 long
No diff lag or positional
Lembersky VRU 2022
New quantitative rad method for ddx normal vs sublux SI joint
cut off 2deg, using line parallel to cranial endplate of L6 best accuracy
Kang VCOT 2024
2x 2.3mm headless compression screws vs
1x 3.5mm cortical lag screw
smaller double HCS may be beneficial (max load higher than single lag screw)
Froidefond VS 2023
15 cats bilateral SI with transiliosacral toggle
No major comp
anatomic reduction good and comparable to other techniques