ServSafe Manager Chapter 9 Flashcards
What are the interior requirements for FLOORS, WALLS, and CEILINGS?
should be smooth and durable for easy cleaning
regular maintenance
floors need to have coving
standing water needs to be removed immediately on floors when cleaning
What is COVING?
a curved, sealed edge between a floor and a wall used to get rid of sharp corners or gaps that can be hard to clean
Who/what is NSF INTERNATIONAL?
an organization that creates national standards for when foodservice equipment comes into contact with food
What/what is ANSI
American National Standard’s Institute
provides accreditation for NSF
standards for food equipment require that it be nonabsorbent, smooth, and corrosion-resistant, as well as easy to clean, durable, and resistant to damage
What are the requirements for FLOOR-MOUNTED EQUIPMENT?
legs must be at least 6 inches high or sealed to a masonry base
What are the requirements for TABLETOP EQUIPMENT?
legs must be at least 4 inches high or sealed to the countertop
What are the guidelines for HANDWASHING SINKS?
put in areas where staff wash their hands frequently
required in restrooms or directly next to and in areas used for food prep, service, and dishwashing
only used for handwashing purposes
must include adequate barriers, distance between handwashing sinks and food/food-contact surfaces so water cannot splash on the items
What are the requirements for handwashing stations?
hot/cold running water
soap
way to dry hands
garbage container
signage
What are the sources that water can come from? (4)
approved public water mains
private water sources that are regularly tested and maintained
closed, portable water containers
water transport vehicles
Define CROSS CONNECTION
a physical link between safe water and dirty water, which can come from drains, sewers, or other wastewater sources
Define BACKFLOW
the reverse flow of contaminants through a cross-connection into a drinkable water supply
Define BACKSIPHONAGE
backflow that is created when high water use in one area of an operation creates a vacuum in the plumbing system that sucks contamination back into the water supply
How to prevent backflow
best way is to avoid creating a cross-connection by:
not attaching a hose to a faucet unless a backflow prevention device is attached, such as a vacuum breaker, or you use other mechanical devices to prevent backflow, such as double check valves and reduced pressure zone backflow preventers
the only sure way to prevent backflow is to create an air gap
Define VACUUM BREAKER
a mechanical device that prevents backsiphonage by closing a check valve and sealing the water supply line shut when water flow is stopped
Define AIR GAP
an air space that separates a water supply outlet from a potentially contaminated source