Series & Parallel and Meter Testing Flashcards
When two or more PV modules are wired in series, voltage is _______ and current is _______ in all parts of the circuit.
additive; equal
When testing the Voc of a module, what is the correct setting for a digital multimeter?
VDC
A clamp-on meter is used to test circuit _________________ .
current
Testing for polarity ensures__________________
the positive and negative conductors are correctly wired and identified
Checking for continuity will reveal if:
a fuse is still operable or if it has blown.
explanation: If a fuse has blown, then there will be no path for current to flow across it, and thus no continuity.
When measuring for correct maximum power current (Imp) of an operating PV array, which two of the following should be used?
pyrometer; clamp-on meter
A crystalline silicon PV module with a maximum power point voltage (Vmp) around 36 volts is likely made up of how many individual PV cells?
72
explanation: Crystalline silicon PV cells typically have an operating voltage around 0.5 volts. Seventy-two of them wired in series would result in a Vmp of approximately 36 volts.
Are typical household loads and appliances that are all on a single circuit wired together in series or in parallel?
parallel
In a series connection, the positive lead of one module connects to the ____________ lead of the next module.
negative
All source circuits connected to a single MPPT must have the same number of modules wired in ___________ so that all source circuits have the same voltage characteristics.
series
To increase the current of a PV output circuit, PV source circuits are connected in _________.
parallel
True or False: When a parallel connection is made, the current remains the same.
false
Two arrays with the same tilt angle, orientation, and amount of shading are wired to separate Maximum Power Point Trackers. Each array consists of ten of the same make/model modules. The first array is wired in a single series string of ten modules. The other is wired in two series strings of five modules each (two circuits in parallel).
True or False: The total available power at STC conditions of these two arrays is the same.
true
Individual circuits of PV modules in series are known as ___________.
PV source circuits
When measuring for correct maximum power voltage (Vmp) of an operating array with electrically insulating gloves, _________________ and _________________ should be used. (choose two)
temperature sensor; probe tips of a digital multimeter