After pump shift is completed put the truck transmission in the proper pump operating range or gear for most pumpers this will be direct drive one to one ratio in addition the speedometer should read ________ mph after the shift has been completed
5 to 15
Caution do not reduce the pressure on the intake gauge to zero; serious damage to the Water Main could result
T
The pump can do ____ then it’s rated capacity with less than 10 foot vertical lift
better
As the vertical lift increases to above 10 feet the maximum pump capacity will be _____
reduced
In general for priming the pump should be operated at idle with an engine speed of about RPMs
1000 -1200
When the pump is primed the _____ indication readings fall below zero, and the discharge pressure starts to increase
intake
Running the engine at speeds higher than ______ RPMs during priming is not recommended , because it will not improve priming operations, running a pump at higher rpm’s will increase wear.
1200
If the pump does not achieve a prime within ____ seconds do not continue to run the priming pump stop the pump and check for air leaks or possible pop trouble
30 sec
Relay operations are necessary when the water source is _______from the fire to be pumped efficiently by one pumper
too far away
Relay pumping is the movement of water through a number of consecutive pumpers from ______
suction to discharge
The number of pumpers in a relay is determined by ____the water source is from the fire
how far
Tandem pumping
Is when you use to pumpers connected ________ with one good hydrant
intake to intake