Section 1 General Fire Fighting Flashcards
How many MSA SCBA air monitoring systems base stations are carried in the district Chief vehicle
2
How many firefighters can each base station monitor
50
Only one SCBA air monitoring system shall be activated at an emergency scene unless the total number of firefighters on air exceed
100
On the air monitoring system what are the percentage of air for green yellow and red
Green above 50%
Yellow between 25 and 50 percent
Read below 25%
In the SCBA monitoring system when will a low pressure alarm sound
When the bottle is at 25%
In the SCBA monitoring system what are the three types of evacuations
Evacuate all
Evacuate team
Evacuate individual
How many times can an evacuation command be sent to a firefighter during a single monitoring session
Once
In the air monitoring system and an event the radio connection is lost it is possible to create a_________ firefighter to simulate the air consumption of the firefighter or company that has lost radio contact
Dummy
If properly said the low pressure audible alarm warning will sound for a dummy firefighter at
1250 PSI
What does the Cure multi gas meter monitor
Oxygen
Hydrogen sulfide
Carbon monoxide
Combustible gases
How many hours of continuous use on one charge when the battery is new can you get out of the q rae -gas monitor
20hrs
How long does the Q Rae meter take to charge
Approximately 10 hours
What is the water capacity of the water can
Two and a half gallons
What type of valve and how much pressure is the water can charge 2
Schrader valve
100lbs
What is the discharge time and reach for the water can
50 seconds and reaches 40 to 50 ft
What are dry chemical extinguishers filled with
30 lb of purple K dry chemical
What is the discharge time for the dry chemical extinguisher
11 seconds
What is the coverage area for the dry chemical fire extinguisher
30 square feet
What type of fire is the dry chemical extinguisher used
Primarily for class B and C Fires limited class A fire application
When are fire extinguishers to be inspected
Extinguishers are to be checked at the beginning of each tour and thoroughly examined every month and shall undergo in-depth service once every 6 months
How high do you fill the purple k
3in from the cap threads
The company should keep________ pounds of dry chemical and_________ spare CO2 cartridges in quarters for servicing and refilling
50 lb
1 spare cartridge
What is the discharge time and reach for the CO2 extinguisher
Discharge time is approximately 12 to 15 seconds with a 3- 8-foot reach
What type of fire is the CO2 extinguisher used on
Class B and Class C Fires