when should the relief valve open during a Storage Tank relief valve (RV-1) test
45-55psig
when should the relief valve open during the Transfer Tank relief valve (RV-2) test
88-106psig
when should the relief valve open during the Fill Line relief valve (RV-3) test
75psig ± 10
how full should the Transfer tank be when performing the transfer tank relief valve test
1/4 full
when performing the evaporator loss rate test(by Depot), how long should the storage tank/unit be left undisturbed
12/24hr
how full should the Storage tank be when performing the storage tank piping bubble test
1/2 full
when performing the storage tank piping bubble test, what psi should be maintained in the tank
45psig
how full should the transfer tank be when performing the transfer tank piping bubble test
1/2 full
when performing the transfer tank piping bubble test, what psi should be maintained in the tank
85psig
when using teflon tape, what thread would you start at the prevent contamination
3rd thread
Storage Tank relief valve (RV-1) test pressure
58psig
Transfer Tank relief valve (RV-2) test pressure
106psig
probably causes excessive frost or condensation on the lines
automatic opening of the relief valve, tank not level, leaking valves, vacuum deterioration