SCBA Manual Chapter 7 Air Unit SOPs & Guidlines - Sheet1 Flashcards

1
Q

From SCBA:

Air units come under the operational commands of the captains of which fihouse

A

E4 /E8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

From SCBA:

Who will assist in having a certified Tech render repairs to the air compressor?

A

Safety Officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

From SCBA:

How many air compressors does the dept have?

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

From SCBA:

Where are the air compressors lcoated

A

E4/E8/TA & Air 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

From SCBA:

What is the primary function of the air units?

A

provide full SCBA air cylinders and full o2 bottles at the scene of emergencies

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

From SCBA:

How many Secondary functions are there?

A

8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

From SCBA:

What firehouse are the exchange or bottles done at?

A

BFC quarters & locations with SCBA storage rakcs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

From SCBA:

T or F the air unit assists with teh repair of facepieces?

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

From SCBA:

Which form does the Air Unit check out Daily?

A

FD 54.2AU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

From SCBA:

T or F after ensuring the vehcle is ready for service they call each Battalion Headquarters by 0730?

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

From SCBA:

Air 2 handles which locations?

A

Batt. 1,2,3 & TA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

From SCBA:

Air 2 handles which locations?

A

Batt 4,5,6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

From SCBA:

A company should tag a defective face piece, cylinder or harneddwith and SCBA repair request form and putit where?

A

battalion head quarters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

From SCBA:

Any other time this equipment is needed who is to be contacted?

A

Safety Officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

From SCBA:

how many ready reserve harnesses must be for service on the Air unit

A

5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

From SCBA:

Should the need for more harness be needed, where shoudl they be obtained?

A

Mask Room

17
Q

From SCBA:

T/F a journal is tobe kept of the Air Units actions

A

TRUE

18
Q

From SCBA:

What is in this journal

A

Number and type of air cylinders, o2 bottles replaced and and field repairs peformed and any other relevant info to work performed

19
Q

From SCBA:

Air Unit Tech’s will wipe down cylinders with water prior to refilling. If additional cleaning is required who must they contact

A

mask room tech

20
Q

From SCBA:

Upon Arival to an Emergency scene what 3 steps should the Tech take?

A
  1. Notify Communications or Uncident COmmants by radio of the units location on scene 2. Report to the command post with pat tag and portable radio 3. Operate as ordered by IF or their designee
21
Q

From SCBA:

Rounds for Air 1 include which houses?

A

E4,11,16,22,20

22
Q

From SCBA:

Rounds for Air 2 include which houses?

A

E8,12,15, TA

23
Q

From SCBA:

Information on faulty equipment should have a repair request form - what info should be on it?

A

date, company number, harness IS, OIC of company reporting the defect and their platoon and signature

24
Q

From SCBA:

The other location to fill cylinders in the district is located on what base?

A

Bolling AFB (202) 767 5407

25
Q

From SCBA:

If there is a malfunction with the compressor after hours who’s to be notified?

A
  1. Company officer of housing compressor. 2. Safety Officer
26
Q

From SCBA:

What 3 pre-operation steps should be done before operating a compressor

A
  1. Turn the master switch to the off position. 2. Check oil level using the dipstick. 3. Check white waste container - if its full do not operated the compressor and notify the S.O.
27
Q

From SCBA:

How many steps are there for compressor operations?

A

26

28
Q

From SCBA:

T/F if the compressor isn’t run for a few days it would trigger a CO alert

A

TRUE

29
Q

From SCBA:

What is the fill rate for the SCBA bottles?

A

1000-1500 psi/min

30
Q

From SCBA:

T/F If you fill a cylinder too fast it will suffer a pressure GAIN after it cools.

A

False- pressure loss up to 500psi

31
Q

From SCBA:

In extreem humid temperatures the bump button is used to clear out the system of moisture - how often is that dump and for how long shoudl you hold the button

A

8-9 minutes and hold for 30 seconds

32
Q

From SCBA:

Before operating a compressor members shall check WHAT to how often the service is performed

A

Compresor Journal - serviced quarterly

33
Q

From SCBA:

If the system malfunctions the member shoudl notify the S.O. Company officer and mask room of what 5 things?

A

How long it was in use prior to the problem, did it shut itself off, was the emergency button or master switch used to shut it down, what lighst were on the info panel, what noise if any did it make?