S12 Flashcards
A sprinkler system is a fire extinguishing system that uses:
Foam as an extinguishing agent
Air as an extinguishing agent
None of the answers are correct
Water as the extinguishing agent
Water as the extinguishing agent
Regarding the exposed piping and control valve handles of the fire protection systems not including horizontal branch lines, which statement is ?
The exposed piping on a standpipe system shall be painted red.
All valve handles serving a dedicated sprinkler system shall be painted green.
All valve handles serving a standpipe and sprinkler system shall be painted yellow.
All exposed piping on a dedicated sprinkler system or standpipe system shall be painted green.
The check valves of a water storage tank must be inspected by a Certificate of Fitness holder at least every__________.
The check valves of a water storage tank must be inspected by a Certificate of Fitness holder at least every__________.
2 years
5 years
3 years
4 years
Who is limited to inspect residential occupancies with 30 sprinkler heads or less without booster pump?
MFSPC
Chief Engineer
Building owner
Master plumber with the S-12 C of F
At least once every _______ years the Fire Department Connections for any sprinkler or standpipe system must be subjected to a hydrostatic flow and pressure test.
3
10
7
5
A hydrostatic test performed by a Master Fire Suppression Piping Contractor has to be done in the presence of who of the following?
Master plumber
Fire Life Safety Director
Building owner
Fire Department representative
Fire Department representative
Lateral braces shall be spaced at a maximum of ________ feet on centers and are required on all piping 2 ½ inches and larger.
40 feet
20 feet
30 feet
50 feet
The low point drain in a dry pipe system shall be drained:_____
Monthly
Daily
Quarterly
Before the onset of freezing weather conditions
Before the onset of freezing weather conditions
According to Local Law 60/2009, who is authorized to remove an inoperable sprinkler system from a building after a damage report has been completed? Permission has to be given by the Fire Department and Department of Buildings.
Registered Design Professional
None of the answers are correct
Master Fire Suppression Piping Contractor
Licensed Master Plumber
Piping passing through holes, platforms, walls, floors, and foundations are required to have a clearance of at least ______ inches around the piping penetration.
6 inches
12 inches
4 inches
2 inches
2 inches
Response Time Index is a measurement of what?
How slow the solder melts during a fire.
How fast the sprinkler system sprays water on a fire.
How fast the deflector spray pattern develops.
The thermal sensitivity of a sprinkler head expressed in meters-seconds.
The thermal sensitivity of a sprinkler head expressed in meters-seconds.
When properly installed and maintained, sprinkler systems have been effective in:
96% of fire incidents
100% of fire incidents
50% of fire incidents
85% of fire incidents
96% of fire incidents
When a Certificate of Fitness holder observes a minor defect, it shall be reported to the building owner. If the condition is not corrected in _______ days, it shall be considered impaired and reported in writing to the FDNY.
7
20
30
15
30
What is an accurate statement regarding the main control valve?
Can be closed by the Fire Life Safety Director at any time.
Should not be closed except on the order of the fire officer in charge during a fire condition.
Is not designed to control the flow of water in the system.
Should never be locked and chained in the open position.
When gravity tanks are installed on the premises they:
Only provide water for domestic water needs.
Are a reliable water supply source for a standpipe and sprinkler system.
Do not require the installation of an overflow pipe.
Cannot be used in conjunction with pressure tanks.
Are a reliable water supply source for a standpipe and sprinkler system.
An out of service condition caused by a pipe break in the sprinkler system is considered a(n):
Planned out of service condition
Unscheduled out of service condition
Minor defect condition
Unplanned out of service condition
Unplanned out of service condition
Some sprinkler heads are made of metal,and are screwed into the piping at standard intervals. What size is the opening through which the water is discharged in a standard sprinkler head?
1/2 inch opening
3/4 inch opening
1/4 inch opening
1 inch opening
1/2 inch opening
Sprinkler heads exposed to corrosive conditions are often covered with a protection coat of:
Metal or potassium
Wax or lead
Copper or aluminum
Lead or brass
Wax or lead
When planning to remove a fire protection system out of service, who is made aware of and authorizes the placing of systems out of order?
None of the answers are correct
The FDNY commissioner
The C of F holder and impairment coordinator
The building owner
Ice build-up on gravity tanks:
Can cause the tank to collapse
Does not weaken the tank supports
Should not be removed
Would be appropriate under certain conditions
Systems that are out of service, both planned or unplanned, should be IMMEDIATELY identified by placing a service tag at:
System control valves
All of the answers are correct
The Fire Command Center
Fire Department Connections
All of the answers are correct
Which is NOT a benefit of an automatic sprinkler system?
Automatic suppression of a fire
Reduction in insurance premiums
Automatic notification to a master plumber
Automatic notification to the Fire Department
Automatic notification to a master plumber
Before a fire protection system is restored to normal service, the person who will ensure that the necessary tests and inspections were conducted to verify the system is operational, and will make the proper notifications, and remove the out of service tags and disks is the:
Impairment coordinator
C of F holder
Building owner
Master plumber
After 30 days, any defects that have not been corrected shall be reported to whom?
The C of F holder
Fire Department Borough Communications Office
Management company
Department of buildings
Fire Department Borough Communications Office
___________ above ceilings with cover plates are commonly found in many buildings. They provide a finished look and also protect the sprinkler heads from accidental contact and possible activation.
Concealed sprinkler heads
Pendent sprinkler heads
Sidewall sprinkler heads
Glass bulb sprinkler heads
Concealed sprinkler heads
The quick response sprinkler has a:
4 mm glass bulb
3 mm glass bulb
2 mm glass bulb
5 mm glass bulb
3 mm glass bulb
A listed device is a fire protection component that has passed which of the following:
A list of monthly inspections
A performance test conducted by a nationally recognized testing agency
None of the answers are correct
Five year hydrostatic flow and pressure test
A yard hydrant system can have which of the following water supply sources?
A sprinkler system and a hose system
A gravity tank and pressure tank
A standpipe system and fire hydrants
All of the answers are correct
All of the answers are correct
Pressure tanks are normally kept at a minimum of 75 PSI of air pressure and they are also kept:
None of the answers are correct.
One-third full of water and two-thirds full of air.
One-third full of air and one half full of water.
One-third full of air and two-thirds full of water.
The strainer, filter, or dirt leg of the fuel system for a diesel engine system fire pump must be cleaned:
Semiannually
Annually
Quarterly
Monthly
During the _______ trip test, the interior of the preaction or deluge valve shall be cleaned thoroughly and the parts replaced or repaired as necessary._____
Quarterly
Annual
Monthly
Semiannual
Annual
Preaction systems are usually employed in which type of locations?
Residential buildings
Loading dock or garage area
Areas that are at risk for serious water damage due to broken pipes.
Commercial buildings
At a distance of four feet below the deflector, the spray covers a circular area having a diameter of approximately how many feet when the sprinkler is discharging 15 gallons per minute (GPM):
16 feet
18 feet
20 feet
12 feet
A recessed sprinkler head is one that:
All of the body is below the ceiling
Directs the water against the sidewall
All or part of the body is above the ceiling
Only part of the body is below the ceiling
The solder is designed to melt when the temperature in the room reaches a predetermined level. When the solder melts, the levers and links separate and the sprinkler head opens. When this occurs the sprinkler head is said to have:
Tripped
Linked
Fused
Activated
If your building has a water storage tank that does NOT have a water level alarm, the condition of the water must be checked by a Certificate of Fitness holder at least ______.
Weekly
Monthly
Quarterly
Daily
MONTHLY
Seismic restraints adopted after 1998 by the NYC Building Code are used with a sprinkler system for what purpose?
All of the answers are correct
Fire Protection
Earthquake surge protection
Hurricane Protection
Sprinkler booster pumps:
Are the same as jockey pumps.
None of the answers are correct.
Are installed for the purpose of boosting the city water pressure in the sprinkler system.
Are never used in sprinkler systems installations.
The vertical turbine pump:
Utilizes a strainer to remove solid particles from the water.
All of the answers are correct.
Has the capability to draw a source of water from wells, rivers, and reservoirs.
Is a modified centrifugal pump that does not require the suction to be under pressure.
ALL OF THE ANSWERS ARE CORRECT
What is the control valve called that is connected to the entire main water supply grid in a yard hydrant system?
OS&Y valve
Preaction valve
Gate valve
Post indicting valve (PIV)
Control valves shall be maintained _______ by an MFSPC with S-15 C of F.
Annually
Monthly
Quarterly
Semiannually
A fire pump uses a power source to draw a water supply under high pressure into the fire protection system. For this to work properly, the pressure must be at least ______:
15 PSI
10 PSI
20 PSI
25 PSI
What is used to indicate that a system or portion of a system is out of service?
Cards
Valves
Tags
Handles
TAGS
Which of the following activities are prohibited for sprinkler system hanging components?
All of the answers are correct
The use of nails to fasten the system to the structure.
The use of makeshift hangers, such as strapping or bailing wire.
The use of hangers with plastic piping that are not listed for use with the piping material.
ALL OF THE TAGS ARE CORRECT
Quick opening devices shall be maintained _______ by an MFSPC with S-15 C of F.
Monthly
Annually
Semiannually
Quarterly
Under normal conditions, the pipes in the non-automatic sprinkler systems are dry. Water is supplied when necessary by pumping water into the system through the:
Gravity tank
The Fire Department Connection
Jockey pump
Roof manifold
A listed device is a fire protection component that has passed which of the following:
None of the answers are correct
A performance test conducted by a nationally recognized testing agency
A list of monthly inspections
Five year hydrostatic flow and pressure test
During the _______ trip test, the interior of the preaction or deluge valve shall be cleaned thoroughly and the parts replaced or repaired as necessary._____
Quarterly
Monthly
Semiannual
Annual
Which of the following would best described a yard system?
Only sprinklers are used in a yard system.
Only standpipes are used in a yard system.
A layout of a yard where there is a need for a standpipe or sprinkler system, but the public water supply does not meet the demands of the fire protection system.
A place where people park trucks.
The garbage compactor sprinkler system C of F holder should know the location of all sprinkler heads on the premises, including:
All of the answers are correct
Supply lines
Compactor rooms
Control valves
ALL OF THE ANSWERS ARE CORRECT