What is the function of the RAT and EMER GEN pushbutton?
AUTO - RAT will automatically extend if AC BUS 1 and 2 are not powered, and airspeed > 100 knots.
MAN - Extend RAT at any time
How long does it take the RAT to extend and provide power?
8 seconds
3 seconds for RAT extension; 5 seconds to pressurize the Blue Hydraulic System and power the EMER GEN
What happens when you push the GEN 1 LINE pushbutton?
A. GEN 1 Line Contactor opens and the white OFF light illuminates
B. AC BUS 1 is powered by GEN 2 through the BUS TIE CONTACTOR
C. GEN 1 continues to power 1 fuel pump in each wing tank
What does the amber SMOKE light in GEN 1 LINE pushbutton indicate?
Smoke detected in the avionics ventilation ducting
With the APU green AVAIL light on and the EXT PWR blue ON light illuminated, which system is powering the aircraft?
EXT PWR
With both engines off and the EXT PWR and APU both displaying “AVAIL” light, how is AC BUS 2 being powered?
APU
Which valves will receive a close command when the DITCHING pushbutton is depressed?
ARPO
A. Avionics Inlet and Extract valves
B. Ram Air Inlet
C. Pack Flow Control Valves
D. Outflow valve (only if in AUTO mode)
When the mode selector is out of the AUTO position, how do you set a landing elevation?
Manually by selecting landing elevation via the LDG ELEV dial
What would cause an amber FAULT light to illuminate in the PACK 1 and/or PACK 2 pushbutton?
OOD
A. Overheat - Pack outlet
B. Overheat - Compressor outlet
C. Discontinuity - Switch position disagreement
Note: FAULT light will be illuminated when no bleed air is supplied
At what cabin differential pressure does the RAM AIR valve open?
1 PSI differential pressure or less
What does an amber FAULT light in the HOT AIR pushbutton indicate?
Duct overheat - the Hot Air and Trim Air valves close automatically
When performing the PRELIMINARY FLIGHT DECK PREPARATION, what is the minimum Battery Voltage?
25.5 Volts
When performing the FLIGHT DECK PREPARATION, what are we looking for on the ELEC panel BAT check?
A. ECAM ELEC page - select
B. BAT 1 and 2 - OFF then ON
C. Check BATT current is <60 amps after 10 seconds and continues to decrease
What does an IDG FAULT light indicate?
A. Oil pressure low (inhibited when N2 <14%)
B. Oil outlet temperature overheat
C. Light is inhibited when IDG is disconnected
How can an IDG be reset?
On the ground by maintenance