Respiratory Supplies Flashcards
What is the maximum amount of oxygen for an adult nasal cannula?
6 liters MAX for a adult nasal cannula
What should you ensure is done before putting
non-rebreather on patient?
Inflate the bag first❗
Connect to O2, hold finger over valve & wait for the bag to be inflated
(This should only take a few seconds)
What is the maximum amount of oxygen for an infant nasal cannula?
2 liters MAX for an infant nasal cannula
How do you pick the correct size of nasal cannula for your patient?
Recommend < 50% of nares occlusion
What is the only respiratory device that you should use humidification with?
ONLY use humidification for nasal cannula set-up
What is the maximum percentage of oxygen for the floor if the patient is using a venturi mask?
50% FiO2 is the maximum for the floor
(if you need more, consider calling an ACT) 🆘
What do you set the oxygen to on the wall when setting up a non-rebreather mask?
CRANK it all the way up ⬆
15 liters is recommended
What size bag/mask would you grab for a patient who is 30kgs?
Adult!
Adult bag/mask for > 20 kgs
(This is specifically for the bag. Mask size is based on whatever size provides the best seal)
Your patient is using a spacer with their inhaler. How many breaths should they take per puff?
6 breaths per puff
Encourage them to take long & deep breaths
if you hear a whistle, they are breathing too fast
What would you set the oxygen meter to for an aerosol administration?
Requires 6-8 liters to operate
Do you connect the aerosol to the AIR or OXYGEN on the wall?
Oxygen if the patient is requiring oxygen prior
Air if the patient is not requiring oxygen
What is the maximum amount of oxygen for a pediatric nasal cannula?
4 liters MAX for a pediatric nasal cannula
What is Metaneb® therapy?
Metaneb® therapy provides for improved mobilization of secretions, improved lung expansion and the prevention and treatment of pulmonary atelectasis.
How do you know what to set the oxygen at for a venturi mask? 🤷♀️
Look at the device – it should be set at either 3 or 6 liters
3 liters
24%
26%
28%
6 liters
35%
40%
50%
How frequently do we change pulse ox positions on H12?
Q8 hours 👍