Residential Wiring Flashcards
A service entrance panel should be mounted how high above finished grade ?
48 to 72 inches
What is connected to a circuit breaker or fuse ?
The underground connector
On what side of the meter socket are the service entrance conductors that feed the service entrance panel connected ?
Load side
The current carrying capacity of a conductor depends on two things what are they ?
The material the wire is made of and the size or gauge of the wire
The size of the service entrance conductors depend on what ?
The total electrical load
What does 14/3 WG on Non-Metellic sheathed cables “Romex” tell you?
Size of the wire , number of conductors , with ground
When wiring a switch leg , the power enters what first ?
The light
A ground conductor will
Never be in series with a fuse , circuit breaker or switch
On a construction site, temporary service may remain in place until ?
The building is ready to receive power through its own panel
What do you call a safety device that automatically shuts off the power when an overload or short circuit occurs and can be manually reset
GFCI
What are 3 types of GFCI’s ?
° portable
°receptacle
°circuit breaker
What or who determines the side of the circuit breaker needed to protect a circuit ?
Gauge of the wire
A GFCI monitors the current balance between ?
Grounded and ungrounded conductors
Another name for a weather head is ?
Service head or service cap
Some light fixtures are center mounted on a threaded metal tube called a ?
Nipple
On a CSR what does the letter M connect to
Run winding
The power company needs how many feet of conductor hanging out of the service head to hook to their drop wires ?
3 to 4 feet
The NEC requires you have a minimum of how many small appliance circuits in a dwelling ?
2
What is the minimum copper wire size and circuit breaker size allowed in a dwelling ?
14 AWG @ 15 amps