Res furn 2 Flashcards

1
Q

What is the main difference between an intermittent pilot gas valve and a direct ignition gas valve?

A

The direct ignition gas valve has no pilot connection.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When using electronic ignition, what is the process of proving the flame called?

A

Flame rectification

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the minimum flame rode to ground electrode area that is immersed in the flame?

A

1:4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Why have flame conductivity systems not been used for proving the flame?

A

The system will not distinguish between a flame and a short to ground.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the first step in the sequence of operation for any heating application with electronic ignition?

A

There is a call for heat at the thermostat.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the importance of the connection diagram?

A

It shows where the wires go and the colour of the wires.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the importance of the ladder diagram?

A

It shows how the appliance works for troubleshooting.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the function of the device identified as ILK?

A

The ILK device shuts off the appliance if the blower door is removed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What device has a capacitor connected to it?

A

The blower motor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How many speeds does the blower motor have?

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What color wires are connected to the limit switches?

A

Red

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the voltage output of the transformer?

A

24 VAC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which motor speed is not used as the unit is received from the factory?

A

MED HI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What size of fuse should be used as a replacement?

A

A three-amp fuse

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How many trials for ignition does this unit have?

A

Four

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

5 parts of a Relay

A
Coil
Core
Return spring
Armature
Contacts
17
Q

List four most common arrangements for the contacts of a relay

A

“SPST - NO” single pole throw normally open contacts
“SPST - NC” single pole single throw normally closed contacts
“SPDT” single pole double throw
“DPDT” double pole double throw

18
Q

Two most common capacitors used in HVAC systems

A

Run capacitor

Start capacitor

19
Q

What is the material called that is used to separate the two plates in a capacitor?

A

Dielectric

20
Q

What activates a pressure switch?

A

The pressure switch is activated when the IDM starts turning and creates enough pressure, it will force the diaphragm to move toward the microswitch, closing it.

21
Q

What is flame rectification?

A

Flame rectification is an AC electrical circuit that sends a very small current from the furnace electronic board-up to the flame rod. When the flame is established, the flame acts as a path or conductor, which allows the current to flow across the flame from the flame rode to ground (burner), thus completing the circuit.

22
Q

Where is the CPU located?

A

The electronic control board contains the CPU in most modern day HVAC equipment.

23
Q

In a cooling unit, where is the high pressure switch located?

A

The switch is located in the tubing between the discharge side of the compressor and the condensing coil.

24
Q

Explain the function of the low pressure switch.

A

The low pressure switch monitors the refrigeration system for a loss of refrigerant charge and may also be helpful in stopping the evaporator (indoor) coil from freezing up due to a dirty filter or low airflow over the coil.