REPUBLIC ACT 9514 (FIRE CODE OF THE PHILIPPINES) Flashcards

1
Q

Any act that would remove or neutralize a fire hazard

A

Abatement/Firewall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

An integrated piping system connected to a source of an extinguishing agent that suppresses fire when actuated by its automatic detective device

A

Automatic fire suppression system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The head of the city fire station or the municipal fire station

A

Fire Marshall=Bldg Official

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Wall designed to prevent the spread of fire having a fire resistance rating of not less than four hours with sufficient structural stability to remain standing even if constuction on either side collapses under fire conditions

A

Firewall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Bdlg. 15 meters or more in height

A

High rise bldg.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A continous and unobstructed route of exit from one point in a bldg. to a public way

Shall be integral or permanently affixed to a bldg

Max width: 915mm

A

Means of egress

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The maximum number of persons that may be allowed to occupy a particular bldg or space

A

Occupant load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A bldg. that is unsafe in case of fire because it will burn easily or becasue it lacks adequate exit

A

Fire trap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

WHAT DOCUMENT THAT Do documentation of safety features written report prepared by the architect and his fire protection consultant and its a compilation of plan and specs and design analysis

A

FALAR 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

WHAT TYPE OF DOCUMENTATION THAT IS submitted by contractor certifying that construction was in accordance with falar 1

Compilation of report included as-built documents given by contractor to owner

A

FALAR 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

TYPE OF DOCUMENTATION
Documentation of required periodic maintenance and upkeeep of faculty

Written report prepared by the building owner and his fire safety officer

Compilation of maintenance and testing records

A

FALAR 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

RELEASED ONCE BLDG. PLANS AND SPECS ARE FOUND TO BE IN ACCORDANCE WITH THE FIRE CODE

REQ. FOR BLDG PERMIT

A

FSEC ( FIRE SAFETY EVALUATION CLEARANCE)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

CERTIFIES THAT THE BLDG. WAS
INSPECTED AND WAS FOUND TO BE OK
REQUIRED FOR OCCUPANCY PERMIT, BUSINESS PERMIT TO OPERATE, PHILHEALTH ACCREDITATION FOR HOSPITALS, DOH LICENSE TO OPERATE

A

FSIC ( FIRE SAFETY INSPECTION CERTIFICATE)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

FIRE CODE Number of exits for occupancy load 0-499

A

2 exits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Number of exits for occupance load 500-1000

A

3 exits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Number of exits for occupance load 1000 or more

A

4 exits

17
Q

FIRE CODE Travel of distance to exits for occupancy of six

A

15 meters

18
Q

Doors maximum threshold height FIRE CODE

A

13mm

19
Q

Door clear opening FIRE CODE

A

710mm-1220mm

20
Q

For exit doors provide FIRE CODE

A

Self-closing doors

21
Q

NOT ALLOWED AS FIRE ESCAPE OR MEANS OG EGRESS

A

LADDER

22
Q

NOTIFIES OCCUPANTS OF THE BLDG. AND WHEN REQUIRED, EMERGENCY FORCES

A

FIRE ALARMS

23
Q

CONCENTRATED USE OCCUPANT LOAD

A

0.65 SQM

24
Q

LESS CONCENTRATED USE OCCUPANT LOAD

A

1.40 SQM

25
Q

STANDING ROOMS/WAITING

A

0.28SQM

26
Q

MINIMUM CORRIDOR WIDTH IF SERVING 50 OR MORE PERSON FIRE CODE

A

1120MM

27
Q

DIMENSION ROWS BACK TO BACK

A

830MM

28
Q

DIMENSION OF SEATING FROM BACK OF ONE SEAT TO THE FRONT

A

300MM

29
Q

SEATS BETWEEN AISLES

A

14MAX

30
Q

SEATS BETWEEN WALLS AND AISLE

A

7 MAX

31
Q

SEATS WITHOUT ARMS

A

600MM