Check for this on Carnie Caps
-Depth of member
-quality of member
-Installed correctly?
Rebar Impalement Cap Minimum Dimensions
4”X4” Square or 4.5” Diameter Circle
Heat, Lot, batch numbers
Heat– refers to a specific melting operation for steel
Lot
Lot–refers to a specific production run (150 Count for Splices)
Batch/Group
batch–smaller than a lot, a subset of lot terms
If any rebar goes over 20’ in height
It needs a temporary structure and is engineered by a PE
Mill Certs For Drill and Bond Dowels
Need certs and own ASTM requirements
Mill Scale
The bluish-grey coating formed after the production of steel
Minimum Center-to-Center Spacing of Rebar
2.5X the diameter of the smallest dimension rebar (Bundled Bars have their own Requirements)
Service Splice
Splice designed to withstand SERVICE LOAD
Ultimate Butt Splice
Splice Designed for areas experiencing ULTIMATE LOADS
Will be found in critical areas (like columns)
Splice Samples–>General Overview
Contractor’s QC Collects 4 from each lot (150 count)
Caltrans QA Collects sample 4 from first lot and then from every 5th lot
Additionally, Tests are needed for preliminary submittals
Lap splice requirements #8 or smaller
45 diameters
Do not lap splice
14 or #18 rebar, hoops, bars where minimum clear distance cannot be achieved
Lap splice for #9, #10, and #11
60 diamters