Reactor Flashcards
HOW MANY A4W REACTOR DOES HST HAVE?
2
WHAT TYPE OF FUEL DO THE REACTORS USE?
Enriched Uranium-235
WHAT ARE THE MAIN STEAM LOADS?
- turbine driven fire pumps 4
- main feed pumps 6
- main circulating water pumps 4
How many distilling units are there?
4 total, 2 in each MMR
low power
Six stage flash type
100,000 gallons per day
What is the difference between POTABLE and FEED water?
- potable water: used for drinking, cooking, bathing, laundry and washing airplanes
- Feed water: high purity, chemically treated water for propulsion plant use. Unsafe for consumption
What are the advantages of a nuclear powered CVN?
- Travel faster
- stay on station longer
- require fewer support ships
- greater mobility and flexibility in tactical maneuvers
- five day faster CONUS to MED than CV’s
- not constrained by carrier propulsion fuel reserves
- no large funnels, more room for big radars
- less detectable without the exhaust plumes
- no infrared signatures of conventional propulsion exhaust
- less corrosion of aircraft from propulsion exhaust
- less vulnerable to fire damage, no fuel in propulsion spaces
- larger fuel capacity to support air ops with almost double the aviation fuel
- almost 50 percent more weapons capacity to support sustained air strikes
How many potable water tanks are there total?
26 total (11 fwd, 15 aft)
How many potable water pumps are there total?
4 total, 2 in each MMR.
Heat transfer process.
Generation
Expansion
Condensation
Feed
Reboiler steam loads.
- 50# service steam system ( galley, hot water heaters
- 100# (laundry) steam system
- 25# steam reducing station
( back up to DU feed heaters )
(LSB)
Line shaft bearing
What does Line Shaft Bearing do?
Supports the shaft.
What does Main Thrust Bearing do?
Transfers thrust from screw to hull, pushes the ship threw the water.
Where is the Strut Bearing?
Located outside the skin of the ship.
What is the function of Reduction Gears?
Reduces the speed of turbine and increases torque to spin the shaft.
SSTG
Ship Service Turbine Generators
Purpose of SSTG?
Provides electricity to the ship.
CTG
Coolant Turbine Generator
Purpose of CTG?
Provide electricity to reactor coolant pumps only.
What is the power output of the CTG?
8000 KW each
How many CTGs are there total?
4 total, 2 in each RAR.
ABT
Automatic Bus Transfer
What does ABT do?
Automatically transfers electrical load to another power supply when normal power supply is lost.
MBT
Manual Bus Tranfer
What does MBT do?
Manually transfers electrical load when normal power supply is lost.
EDG
Emergency Diesel Generators
What is the purpose of EDG?
Back up for SSTG.