REACTOR Flashcards
why does CVN 70 have a double loop reactor/ reboiler?
1) to prevent contamination from the ship from feeding into Reactor
2) to prevent radiological contamination from feeding into rest of ship
Name a load off the reboiler
- scullery steam
- galley steam
- potable water (hot)
- Laundry steam
locations of reboilers?
- 1A shaft alley
2. 4B shaft alley
5 things that come off the steam generator?
- CTG’s
- SSTG’s
- CAT’s
- ME
- Reboiler
what is DFT used for?
- Deareate water to create purer water to minimize corrosion
- net suction
how does DFT deaerate water?
steam blanket on top of DFT water. water is then heated and gases are allowed to come out of solution.
how much ater do the distilling tanks produce?
100,000/400,000 gallons total per day
Heat cycle of a reactor?
Reactor—primary colant—S/G’s—-Staem loads (CTG’s, SSTG’s, CAT’s, ME)—DFT—-Main feed booster pumps—MFP’s—S/G’s
Classify our reactors
A4W (aircraft carrier 4th generation designed by westinghouse)
location of ME’s
1 & 4 MMR1
2 & 3 MMR2
location of SSTG’s
1 & 2 MMR1
3 & 4 MMR 2
Location of CTG’s
1 & 2 RAR1
3 & 4 RAR2
Location of EDG’s
1 & 2 under Repair locker 2
3 & 4 AFT under supply berthing, under RX male berthing
rating of CTG’s
4160 v, 8 MW, 1388 amps, 3 phase
Rating of SSTG’s
4160 v, 8 MW,1388 amps, 3 phase, 60 hz
difference between CTG’s and SSTG’s?
CTG- Variable frequency