RC Frame Systems Explore Flashcards

1
Q

has a complete space frame system but the space frame providing support to gravity loads.

A

Building Frame System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Resistance to lateral loads is provided by

A

shear walls or the braced frame

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Building Frame System:
___m height limitation in Zone 4 when using special RC shear walls or braced frames

A

75

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Building Frame System:
___ m height limitation in Zone 4 when using intermediate RC shear walls or braced frames

A

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

t or F
Building Frame System:
Ordinary RC shear walls or braced frames not permitted for Zone 4

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A structural system with an essentially complete space frame providing support for gravity loads
also provide resistance to lateral load primarily by flexural action of members

A

Moment Resisting Frame

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

t or f
Moment Resisting Frame:
No height limitation in Zone 4 when using special RC moment-resisting frames; intermediate and ordinary RC moment-resisting frames not permitted for Zone 4

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Moment Resisting Frames may be classified as:

A

a) Special Moment Resisting Frames (SMRF)
b) Intermediate Moment Resisting Frames (IMRF)
c) Ordinary Moment Resisting Frames (OMRF)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Expected to withstand limited inelastic deformations
Doesn’t require use of prequalified connections per AISC
Not required to be tested
typically used in non/low-seismic regions

A

OMF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Expected to withstand moderate inelastic deformations
Require use of prequalified connections per AISC
Must sustain inter-story drift angle of a least 0.02 radians
typically used in low/mid-seismic regions

A

IMF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Expected to withstand significant inelastic deformations
Require use of prequalified connections per AISC or verified with testing
Must sustain inter-story drift angle of a least 0.04 radians
typically used in mid/high-seismic regions

A

SMF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Structural systems designated as part of the seismic-force-resisting system including _________, _________, __________, and __________.

A

Diaphragms, Moment frames, structural walls, and foundation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly