Random Flashcards
When battling a fire on the exterior of an EFIS-clad building, a knowledgeable officer should know which appliance has the greatest vertical reach (from the top of tip of the nozzle)
Tower Ladder Monitor
As and Officer, you become aware of a member of your unit misusing and/ misappropriating the Department’s time. You would be correct to take which action?
Written notification to BITS
Acronym : IM MAC
Incompetence Misconduct Misuse Arrest Charges
Company officers shall notify the next level of command when a detail from within the Borough does not arrive within ________ or a detail from another borough does not arrive in _________.
- 1 hr - same borough
- 2hr- another borough
* or a member returns from a detail under the same conditions.
FFP MD
3.2
Excite use caution when using ______ suction so as not to block out arriving ladder apparatus.
Which inlet should be used?
- Front suction (exercise caution)
2. Place the apparatus as close to park cars as possible and use the SIDE suction inlet.
FFP MD
3.2
In most case, the first line is stretched via the interior stairs to the location of the fire. The purpose of this line is to protect the primary means of egress for occupants evacuating the building and to confine and extinguish the fire.
What would be the exception ?
When flames are issuing from window opening onto the fire escape and endangering people trying to come come down.
1st line- may be operated from the street to protect people on the fire escape.
2nd line- should be promptly stretched to the interior of the building.
FFP MD
3.3
The ladder company officer or Forcible Entry Firefighter should carry the ________ in order to expedite entry into the many apartments which will be found in these buildings.
K-Tool
FFP MD
3.3
Discretion should be used in the breaking of windows in apartments not involved in fire. Efforts should be made to open these windows _____’ from the top and _____ from the bottom to allow heat and smoke to vent and cool air to enter the room.
2/3 from the top 1/3 from the bottom.
FFP MD
3.3
No material shall be thrown onto roofs of ________ or into _________.
- Roofs of building setbacks
Or
- Into Narrow Shafts.
FFP MD
3.2
When can a roof line be used?
- Prevent fire from extending past the trench.
- To protect exposures.
- Extinguish fire that cannot be reached from below, such as fire in a CORNICE.
FFP MD
3.3
When decision has been made to cut the roof, if possible the _____ side of the opening should be at _______ to the roof beams in order to provide venting if as many bays as possible.
- Long side of the opening
2. Right Angles to the roof beams
FFP MD
3.3
When fire is on the top floor or in the cockloft, suffice t firefighters with hood must be sent to the top floor to pull ceilings, especially for the larger non-fireproof multiple dwellings.
It’s may be necessary to use :
Engine companies for this purpose or to special call additional ladder companies
FFP MD- OLT
4.1.6
The absence of a fire escape on the front of an OLT will usually indicate that the apartments are :
Railroad flats
- they have two entrance doors in the interior hall.
- corner buildings may be exceptions to this general rule.
FFP MD- OLT
4.1.2
At least _______ length of hose should be bought up to the fire floor and the ______ attached.
- First length of hose
2. Hose strap attached to prevent hose from slipping back down the well hole of the stairway.
FFP MD- OLT: Cellar Fire
Where does the first line got at a cellar fire in an old law tenement ?
The first line is should be stretched To the cellar entrance door which is inside the building, under the interior stairway on the FIRST FLOOR.
This line should not be advanced down the cellar stairs if there is an OUTSIDE entrance to the cellar at the front or rear of the building, unless the fire is minor.
FFP MD- OLT Cellar Fire
4.2.1
At a minor fire, can the first line be stretched down the basement stairs ?
Yes
FFP MD- OLT Cellar Fire
The first line should not be advanced down the cellar stairs if there is an:
Outside entrance to the cellar at the FRONT OR REAR of the building, unless the fire is minor.
FFP MD- OLT: Cellar Fires
Where is the second hose line stretched at an OLT with fire in the cellar?
The second line stretched should be advanced into the cellar by way of the front or rear entrance to the cellar
Communications Ch 13 ARCS
True or False
Failure of the related system, for any reason, will also negate all communications on the repeater channel.
True
Note: Repeater systems also fail without warning. There will be NO AUDIBLE warning on the HT or VISUAL INDICATION in the lobby that the related system has failed or is on the verge of failing
Communications Ch 13 ARCS
It’s is critical that members taking a proprietary radio _______________________________.
Perform a functional test with the Lobby Command Post Prior to departing.
Communications Ch 13 ARCS
Will transmissions from proprietary handi-talkies appear on EFAS?
No.
EFAS does not have a scan function. It is programmed to FDNY specific frequencies only.
Communications Ch 13 ARCS
To activate building ARCS, insert a ________ key into the DRC and rotate the one position CLOCKWISE.
1620 Key
Communications Ch 13 ARCS
What is the Primary H/T building repeater channel?
Channel 11
Communications Ch 13 ARCS
What is the Secondary H/T building repeater channel?
Channel 12
Communications Ch 13 ARCS
Upon arrival of the 2nd Battalion Chief to operations Post, all members of the 1st ladder shall:
Return H/T’s to HT-1
Remember: prior to their arrival the 1st Ladder Officer will active the ARCs. Ensure a functional test prior to leaving the lobby and designate a FF or switch his/her HT to the building Primary duplex UHF repeater channel (channel 11)
Communications Ch 13 ARCS
System fail:
As an officer what should you do if you experience an unusual period of silence and believe the ARCS system has failed
Prior to abandoning the use of an ARCS channel, Chief and Company Officers shall instruct units to RETURN TO A LOCATION WHERE PREVIOUS COMMUNICATION WAS SUCCESSFUL.
Communications Ch 14
Who initiates contact first when a CFR unit arrives and an EMS unit is already on scene?
The CFR
Note: The unit arriving second will initiate contact
Communications Ch 14
When are Fire personnel able to contact the EMS dispatcher via Fire apparatus?
Only to communicate CRITICAL INFORMATION
NOTE: use plain speak / no 10-codes
AUC 5
Combination standpipe valve handles must be painted :
Yellow
AUC 5
Dedicated sprinkler valve handles must be painted:
Green
AUC 5
Who do you notify if a standpipe system is discovered to be Out of service during an operation/ inspection and no responsible party is present ?
Fire Marshals
AUC 5
Street Festivals and outdoor gatherings :
Fire hydrants and fire alarm boxes shall be maintained free of signs or other articles or obstructions. The promoter of the event shall conspicuously mark a ________________
Solid Yellow circle 12 inches in diameter
AUC 180
Only ______ can order the application of FireIce.
A Chief Officer
Note: This is normally after consulting with on-scene Con Edison supervisor.
AUC 180
FireIce units will be designated by the letter suffix “__”
“ I “ Eg E290I
AUC 180
FireIce is not effective on class ____ fires.
Class B
Never use on any type of transformer fire
AUC 180
What is the optimal nozzle pressure for FireIce ?
60-80 psi