Quizes Flashcards
The ____ alarm system is generally used in schools, hospitals or facilities where security personnel are on premises 24 hours a day.
supervisory
List 3 categories into which all security alarm systems can be placed
Local, supervisory, central station
What type of detector is designed to prevent false alarms?
dual technology
What types of facilities are protected by central station alarm systems?
commercial business
Which of the following best describes the break gap of a normally closed magnetic switch?
Distance between the magnet and contact when the circuit opens.
A ____ switch can be used to trigger an alarm when someone has opened a security system control panel door.
tamper
What types of indication devices are used with local area alarm systems?
- light, sirens
- bells
- telephone dialers
What is the best mounting location on a door for a roller plunger switch?
hinge side of the door
How much time does an acoustic sensor have to determine whether a sound is a glass break event or a false alarm
one tenth of a second
Why should you field test acoustic sensors?
to ensure proper operation and location of the sensor
In order to trip, a PIP detector requires a ____ degree change in temperature.
3.6
A ____ card is a credit card type used to control access to a specific area.
magnetic strip
What type of security protection is intended to provide protection to one specific location?
area
The alarm ____ is used as a remote burglar alarm indicating device.
bell
One benefit of bright lights and loud bells is that they produce ____ effect which tends to drive the intruder away from the protected area.
psychological
what type of motion sensor does not emit any energy of its own?
PIP
Where is the best mounting location for a motion detector?
In an area where there is a high probability of an intruder crossing its path.
What type of glass breaks into large jagged pieces?
plate
What frequencies travel through breaking glass, surrounding frame and walls?
shock frequencies
What is the most common type of lens found in a PIR?
Fresnel
A pyroelectric sensor is a
transducer
Acoustic sensors can only detect glass which is in ____ with the sensor.
direct line of slight
A term used to describe a locking device that unlocks when there is a power or equipment failure is ____.
fail safe
Another name for an ambush code is ____.
duress code
which of the following detectors is most affected by ambient temperature change?
PIR
Duct detectors are usually required on systems with a capacity over ____.
2,000 cfm
Which of the following are usually found on shop drawings?
- device addresses
- cable/conductor routing
- cable schedules
Secondary power supplies must supply power to protected premises fire alarm systems for a minimum of ____-
24 hours of standby time followed by 5 minutes of alarm
A blocking diode is used to prevent monitoring current from passing though ____.
notification appliances
Visual notification appliances used for public mode signaling (for the hearing impaired) must be listed to UL ____.
1971