1
Q

A manual fire alarm system that activates the occupant notification system shall be installed in Group A occupancies where the occupant load due to the assembly occupancy is:
50 pr more
150 or more
300 pr more
100 or more

A

300 pr more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Doors opening onto a stairway landing shall not reduce the landing to less than the required width.

One half
One fifth
One third
One quarter

A

One half

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A landing serving a ramp shall have a slope no greater than ______?

1 in 12
1 in 8
1 in 18
1 in 48

A

1 in 48

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Automatic sprinklers are permitted to be installed in which of the following locations:

Machine rooms
Elevator hoist-ways of fire service access elevators
Elevator machinery space
Atriums

A

Atriums

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The triangular opening at the open sides of a stair, formed by the riser, tread and bottom rail shall not allow passage of a sphere:

12 inches
8 inches
6 inches
4 inches

A

6 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the maximum slope of a ramp used as part of a means of egress?

1 in 18
1 in 10
1 in 12
1 in 8

A

1 in 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the maximum that a stair doorway may reduce the required width of a landing?

1/4
3/4
1/2
1/3

A

1/2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the greatest height of a threshold at a sliding doorway in a dwelling unit?

1inch
1/4 inch
1/2 inch
3/4 inch

A

3/4 inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the required clearance between a handrail and a wall?

1-3/4 inches
1-1/4 inches
1 inch
1-1/2 inches

A

1-1/2 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the opening limitation to allow passage of a sphere at the triangular opening formed by the stairway riser tread and bottom rail?

10 inches
4-3/8 inches
4 inches
6 inches

A

6 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Doors that are automatic closing by smoke detection shall not have more than a delay before the door starts to close after the smoke detector is actuated.

10 second
15 second
20 second
5 second

A

10 second

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the greatest height in inches of a threshold at a non sliding doorway in a dwelling unit?

1/2 inch
1/4 inch
5/8 inch
3/4 inch

A

1/2 inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Delayed egress locks are permitted in which of the following occupancies?

A
B
E
H

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the height in inches of a handrail serving a stairway or ramp?

34 and 36
34 and 38
30 and 34
32 and 36

A

34 and 38

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where a landing serves an occupant load of 50 or more, doors in any position shall not reduce the landing to less than:

The minimum required width
One quarter it’s required width
One half its required width
36 inches

A

One half it’s required width

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Guard shall be located along open sided walking surfaces, including mezzanine, equipment platforms, ailes, stairs, ramps and landing that are located more than measured vertically to the floor or grade below.

18 inches
36 inches
30 inches
24 inches

A

30 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What is the risk category of a building designed for the occupancy as fire rescue?

IV
III
II
I

A

IV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

From where is the height measured for the placement of a manual fire alarm box?

From the floor to the bottom of the box
From the floor to the top of the box
From the floor to the activating handle
From the floor to a midpoint with the ceiling

A

From the floor to the activating handle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the minimum length of a landing serving a ramp, excluding exceptions?

36 inches
72 inches
48 inches
60 inches

A

60 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What is the minimum net clear opening, in square feet, of an emergency scape opening located at grade level?

6.7
6
5.7
5

A

5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is the minimum thickness, in inches of veneer applied to metal siding for corrosion resistance?

0.019
0.013
0.025
0.0149

A

0.0149

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

According to the IBC, clear space between a handrail and a wall or other surface shall be no less than:

1-1/4 inches
1 inch
1-1/2 inches
1-3/4 inches

A

1-1/2 inches

23
Q

A building with aggregate roofing in an area with a nominal design wind speed of 110 mph in exposure category C can have a maximum roof height of how many feet?

30
15
NP
20

24
Q

Where a ceiling is applied directly to the underside of roof rafters, what spacing is required between the roof sheathing and the insulation?

1-1/2 inches
1/2 inch
1 inch
No space is required if there is a vapor barrier

25
What are the glazing requirements in a fire door assembly? Glazing is not allowed in a fire door assembly Is limited to 100 sq in if it can resist transmittance of 350 degrees F May be over 100 sq inches if tested as part of the assembly Limited to under 100sq inches
May be over 100 sq inches if tested as part of the assembly.
26
What is the minimum clear width, in inches, of an egress door? 48 36 32 41.5
32 inches
27
The latch on a door must be panic hardware equipped in which of the following occupancy F M B A
A
28
Waterproofing shall be applied from the bottom of the wall to no less than above the maximum elevation of the ground water table. 18 inches 12 inches 6 inches 24 inches
12 inches
29
To what depth must stumps and roots removed from the soil in an area to be occupied by the building? 24 inches To the frost depth 12 inches 16 inches
12 inches
30
Doors, when fully opened, shall not reduce the required width by more than 7 inches. Doors in any position shall not reduce the required width by more than: 12 inches One half 18 inches One quarter
One half
31
Swinging doors serving a Group H occupancy and swinging doors serving rooms or space with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than: A lock with an elongated handle Emergency escape hardware Panic hardware or fire exit hardware One that requires a special key or tool to unlock
Panic hardware or fire exit hardware
32
What is the required minimum net glazed area, in percentage of the floor area, in square feet, that provides natural light to a room 8 8.5 5.7 5
8 percent
33
What is glazing greater than three inches in a door considered? Decorative Comercial application Not allowed Hazardous
Hazardous
34
What is the minimum nominal thickness of spaced sheathing boards used as decking for wood shakes? 3/4 inches 1 inch 1/2 inch 5/8 inches
1 inch
35
In Groups I-1 and R-1, how many visible alarm notification appliances are required in a sleeping accommodation with 52 units? 9 2 7 4
7
36
What is the maximum width of a swinging door leaf? 54 inches 36 inches 48 inches 42 inches
48 inches
37
Direction of swing. Pivot or side hinged swinging doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of: 300 or more persons or a group I occupancy. 50 or more persons or a Group I occupancy. 150 or more persons or a Group H occupancy. 50 or more persons or a Group H occupancy.
50 or more persons or a Group H occupancy.
38
What is the minimum length of time that an emergency power system must provide power to a means of egress illumination? 30 minutes 60 minutes 90 minutes 45 minutes
90 minutes
39
Which of the following is incorrect about underlayment for roof slopes of four units vertical in 12 units horizontal ( 4:12 ) or greater? End laps shall be 4 inches and shall be offset by 6 feet. Underlayment shall be 30 lb felt. Underlayment shall be applied shingle fashion, parallel to and starting from the eaves and lapped 2 inches. Underlayment shall be applied in a single layer
Underlayment shall be at least 30 lb felt
40
Each area of refuge shall be sized to accommodate one wheelchair space of for each 200 occupants or portion thereof, based the occupant load of the area of refuge and areas served by the area of refuge. 24 inches by 36 inches 30 inches by 48 inches 36 inches by 49 inches 22 inches by 34 inches
30 inches by 48 inches
41
42
According to the OBC, clear space between a handrail and a wall or other surface shall be not less than: 1 inch 1-1/4 inches 1-1/2 inches 1-3/4 inches
1-1/2 inches
43
Direction of swing Pivot or side hinged swinging doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of: 50 or more persons or a Group I occupancy 150 or more persons or a Group H occupancy 300 or more persons or a Group I occupancy 50 or more persons or a Group H occupancy
50 or more persons or a Group H occupancy
44
What is the minimum thickness, in inches of veneer applied to metal siding for corrosion resistance? 0.025 0.013 0.019 0.0149
0.0149
45
The latch on a door must be panic hardware equipped in which of the following occupancy? M B F A
A
46
Swinging doors serving a group H occupancy and swinging doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with latch or lock other than: Emergency escape hardware Panic hardware or fire exit hardware A lock with an elongated handle One that requires a special key or tool to unlock
Panic hardware or fire exit hardware
47
What is the minimum nominal thickness of spaced sheathing boards used as decking for wood shakes? 1 inch 3/4 inches 5/8 inches 1/2 inch
1 inch
48
To what dept must stumps and roots removed from the soil in an area to be occupied by the building? 24 inches To the frost depth 12 inches 16 inches
12 inches
49
What is the minimum clear width in inches of an egress door? 48 36 41.5 32
32
50
What are the glazing requirements on a fire door assembly? Is limited to 100 sq in if it can resist transmittance of 350 degrees F Limited to under 100 sq in Glazing is not allowed in a fire door assembly May be over 100 sq in if tested as part of the assembly
May be over 100 sq in if tested as part of the assembly
51
Doors when fully opened, shall not reduce the required width by more than 7 inches. Doors in any position shall not reduce the required width by more than: 12 in One half 18 in One quarter
One half
52
What is the maximum rise over ambient temperature of a fire door assembly? Not more than 450 degrees in 30 minutes Not more than 250 degrees F Not more than 450 degrees Not more than 250 degrees F in 30 minutes
Not more than 450 degrees in 30 minutes
53
54