A manual fire alarm system that activates the occupant notification system shall be installed in Group A occupancies where the occupant load due to the assembly occupancy is:
50 pr more
150 or more
300 pr more
100 or more
300 pr more
Doors opening onto a stairway landing shall not reduce the landing to less than the required width.
One half
One fifth
One third
One quarter
One half
A landing serving a ramp shall have a slope no greater than ______?
1 in 12
1 in 8
1 in 18
1 in 48
1 in 48
Automatic sprinklers are permitted to be installed in which of the following locations:
Machine rooms
Elevator hoist-ways of fire service access elevators
Elevator machinery space
Atriums
Atriums
The triangular opening at the open sides of a stair, formed by the riser, tread and bottom rail shall not allow passage of a sphere:
12 inches
8 inches
6 inches
4 inches
6 inches
What is the maximum slope of a ramp used as part of a means of egress?
1 in 18
1 in 10
1 in 12
1 in 8
1 in 12
What is the maximum that a stair doorway may reduce the required width of a landing?
1/4
3/4
1/2
1/3
1/2
What is the greatest height of a threshold at a sliding doorway in a dwelling unit?
1inch
1/4 inch
1/2 inch
3/4 inch
3/4 inch
What is the required clearance between a handrail and a wall?
1-3/4 inches
1-1/4 inches
1 inch
1-1/2 inches
1-1/2 inches
What is the opening limitation to allow passage of a sphere at the triangular opening formed by the stairway riser tread and bottom rail?
10 inches
4-3/8 inches
4 inches
6 inches
6 inches
Doors that are automatic closing by smoke detection shall not have more than a delay before the door starts to close after the smoke detector is actuated.
10 second
15 second
20 second
5 second
10 second
What is the greatest height in inches of a threshold at a non sliding doorway in a dwelling unit?
1/2 inch
1/4 inch
5/8 inch
3/4 inch
1/2 inch
Delayed egress locks are permitted in which of the following occupancies?
A
B
E
H
B
What is the height in inches of a handrail serving a stairway or ramp?
34 and 36
34 and 38
30 and 34
32 and 36
34 and 38
Where a landing serves an occupant load of 50 or more, doors in any position shall not reduce the landing to less than:
The minimum required width
One quarter it’s required width
One half its required width
36 inches
One half it’s required width
Guard shall be located along open sided walking surfaces, including mezzanine, equipment platforms, ailes, stairs, ramps and landing that are located more than measured vertically to the floor or grade below.
18 inches
36 inches
30 inches
24 inches
30 inches
What is the risk category of a building designed for the occupancy as fire rescue?
IV
III
II
I
IV
From where is the height measured for the placement of a manual fire alarm box?
From the floor to the bottom of the box
From the floor to the top of the box
From the floor to the activating handle
From the floor to a midpoint with the ceiling
From the floor to the activating handle
What is the minimum length of a landing serving a ramp, excluding exceptions?
36 inches
72 inches
48 inches
60 inches
60 inches
What is the minimum net clear opening, in square feet, of an emergency scape opening located at grade level?
6.7
6
5.7
5
5
What is the minimum thickness, in inches of veneer applied to metal siding for corrosion resistance?
0.019
0.013
0.025
0.0149
0.0149
According to the IBC, clear space between a handrail and a wall or other surface shall be no less than:
1-1/4 inches
1 inch
1-1/2 inches
1-3/4 inches
1-1/2 inches
A building with aggregate roofing in an area with a nominal design wind speed of 110 mph in exposure category C can have a maximum roof height of how many feet?
30
15
NP
20
NP
Where a ceiling is applied directly to the underside of roof rafters, what spacing is required between the roof sheathing and the insulation?
1-1/2 inches
1/2 inch
1 inch
No space is required if there is a vapor barrier
1 inch