Quiz #5: Q. 126-150 Flashcards

1
Q

The most common instrument used to measure diesel engine exhaust pressure is the __________.

A

manometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In a diesel engine exhaust system, the cooling of the exhaust gases below their dew point, will result in __________.

A

sulfuric acid corrosion

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

One of the factors limiting the amount of load which can be put on a modern marine diesel engine is the __________.

A

exhaust temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Exhaust pipes for separate main propulsion diesel engines can be combined only when __________.

A

they are arranged to prevent gas backflow to each engine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The exhaust system for a turbocharged diesel engine functions to __________.

A

power the turbocharger

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Auxiliary boilers are divided into several classifications, one of which is __________.

A

water-tube forced circulation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In a coil-type forced circulation auxiliary water-tube boiler, __________.

A

steam demand response is comparatively rapid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which of the following statements concerning fire-tube boilers is correct?
A Combustion gases flow through the tubes.
B Flames impinge on the tubes.
C Combustion occurs in the tubes.
D Water flows through the tubes.

A

A Combustion gases flow through the tubes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Bottom blow valves are installed on auxiliary water-tube boilers to __________.

A

remove settled solids from the water drum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The purpose of try-cocks used on an auxiliary boiler is to __________.

A

provide an alternate means of determining the water level, if the gauge glass fails

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

An exhaust gas bypass is installed on a waste heat boiler in order to __________.

A

minimize moisture condensation in the boiler gas passages at low loads

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The maximum pressure developed by a waste heat boiler is determined by the main engine exhaust __________.

A

gas temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Casing drains may be required on a waste heat boiler gas passage side to __________.

A

drain off condensation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

As shown in the illustration, the function of component “1” is to ________. MO-0128

A

evaporate circulating boiler water into saturated steam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

As shown in the illustration, what component would normally be installed at location “D? MO-0128

A

Oil fired mechanical burner

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The boiler shown in the illustration would be classed as __________. MO-0064

A

single-pass, fire-tube, scotch marine

17
Q

The tube sheets installed in a fire-tube auxiliary boiler are normally connected by __________.

A

fire-tubes and stay-tubes

18
Q

Fusible plugs are installed in fire-tube boilers to __________.

A

warn the engineer of low water level

19
Q

Constant capacity, pressure atomizing, fuel burners designed to meet a wide variation in steaming loads on an auxiliary boiler, are __________.

A

cycled on and off in response to steam demand

20
Q

The primary function of a flame safeguard system, as used on an automatically fired auxiliary boiler, is to prevent __________.

A

explosions in the boiler furnace

21
Q

A photoelectric cell installed in an automatically fired auxiliary boiler burner management system __________.

A

opens the burner circuit upon sensing a flame failure

22
Q

The pressuretrol which is installed on an auxiliary boiler senses steam pressure changes and __________.

A

automatically regulates the quantity of oil and air flow to the burner

23
Q

A variable capacity, pressure atomizing, fuel oil burner functions to __________.

A

provide a wide range of combustion

24
Q

The solenoid valves in the fuel oil supply line to an automatically fired auxiliary boiler, are automatically closed by __________.

A

high steam pressure