When an A particle is EMITTED the atomic mass changes by ? A-zero B -minus 4 C-plus 4 D-minus 2
B-minus 4
When a B particle is EMITTED the atomic NUMBER changes by A-minus 1 B-Zero C-minus 2 D-plus 2
D-plus 2
When an A particle is Emitted the atomic NUMBER changes by, A-zero B-minus 4 C-minus 2 D-plus 2
C-minus 2
In X-Ray radiation, intensity is proportionate to ..... A-tube current B-tube voltage C-filament current D-Source to focus to film Distance
A-tube current
The supply of electrons , tube filament is increased by …..
A-increasing the Tube voltage
B-increasing the filament current.
B- Filament current
The factors that determine effective or projective focus size in an X ray tube are :-
A- The diameter of the berylium window and the diameter of the tungsten target.
B- diameter of the electron beam and the angle of the tungsten target with respect to electron beam .
C- the diameter of the Berylium window and the tungsten target with respect to the window
D- The diameter of the electron beam and the diameter of the tungsten target.
B - Diameter of the Electron beam and the angle of the tungsten target with respect to the electron beam .
An electron …..
Carries an electric charge that is equal and opposite to that of a proton.
A beta particle is a high velocity ……
A-neutron
B-helium nucleus
C-electron
D-proton
C- Electron
Compared to X Rays are Gamma rays ,, light ..
A-has longer wavelength and lower Frequency
B-has lower wavelength and higher frequency
C-has shorter wavelength and lower frequency
D-Travels faster
A- Has longer wavelength and higher frequency.
Fixing time should be .. A- 4 minutes B- twice the clearing time C- 2 minutes D- Equal to Dev time
B - Twice the clearing time
Salt or flouro metallic screens have a coating containing ….
A-Sodium iodide
B-Silver Bromide
C-Calcium Tungstate
D-Zinc Sulphide
C-Calcium Tungstate
Scratches on a LEAD screen will produce :-
A-Dark images on the film
B-Light images on a film
D-Sometimes B , usually A
D - Sometimes B , Usualy A
Inherent Unsharpness will INCREASE if :-
A- a fine grain instead of an Ultra fine grain film is used.
B-The radiation source is changed from iridium 192 and COBOLT 60
C-The effective physical side to the radiation is increased .
D-Both A and B
D- Both A and B
Duplex IQI’s are used to :-
A- Measure Unsharpness
B- measure rad sensitivity
C- measure effective source size
D- to measure contrast.
A-To measure Unsharpness
Radiographic contrast will be reduced if :-
A- Film density is increased from 2.0 to 2.5
B- A fine grain film is substituted with an ultrafine grain film.
C- The source to film distance is decreased.
D- The base fog level of the rad film is increased.
D- The base fog level of the rad film is increased
Average grain size of a fine grain film is :-
1 Micron
The main ingredient of Developer is :-
A-Oxidizing agent
B-Reducing agent
C-Acid
D-None of the above
B-Reducing agent
Lead screen decreases exposure time by :-
A- A factor of 10 or 12 at radiation energies exceeding 120 Kv
B- A factor of 5 or 6 at radiation energies exceeding 120 Kv
C- A factor of 4 or 5 at radiation energies exceeding 120 Kv
D- A factor of 2 or 3 at radiation energies exceeding 120 Kv
D- A factor of 2 or 3 at radiation energies exceeding 120 Kv