Questions Flashcards

1
Q

How many inches does one cubic foot contain?

A

1728

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many gallons does a one cubic foot contain?

A

7.5 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

1 cubic foot of fresh water weighs how many pounds?

A

62.5 pounds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

1 gallon contains how many cubic inches?

A

231 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many pounds does 1 gallon of freshwater weigh?

A

8.33 pounds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A column of water one foot high exerts a pressure of _____ psi at it’s base?

A

0.434

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

50 ft length of 1.75 hose contains how many gallons of water?

A

6.24 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

50 ft length of 1.88 hose contains how many gallons of water?

A

7.20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

50 ft length of 2 and 1/2 in hose contains how many gallons?

A

12.74

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

50 ft length of 3-in hose contains how many gallons?

A

18.35

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

100 ft of 4 in hose contains how many gallons?

A

65.25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

100 ft length of 5-in hose contains how many gallons of water?

A

101.94 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Nozzle pressure for hand lines with smooth bore nozzles is _____ PSI

A

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Nozzle pressure for master streams with smooth or nozzles is _______ PSI but can be increased to _______to achieve higher flow rates?

A

80 psi

100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Akron assault nozzles are designed for _____ PSI nozzle pressure and flows _____ GPM with the fog nozzle and ______ Gpm with the 15/16 slug?

A

50 psi nozzle pressure
175 GPM with fog nozzle
185 GPM with the slug

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

This type of pump takes advantage of incoming pressure water enters the eye of the pump then travels through one or more impellers?

A

Centrifugal pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Actual velocity pressure of the water (measured in PSI) for an individual hose line?

A

Discharge Pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

The quantity of water issuing from an opening expressed in GPMs?

A

Discharge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Small positive displacement pump used to evacuate air from a centrifugal pump housing allowing the pump to receive water is called?

A

Primer pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

A stream flowing 350 gpms or more?

A

Master stream

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is the procedure when squaring any number that ends in .5?

A

Identify the two whole numbers at the half number is in between then
Multiply the two numbers together
Add .25 to that

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is the formula for rectangular shaped containers?

A

L X W X D X 7.5
(NUMBER OF GALLONS IN A CUBIC FOOT OF WATER)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What is the formula to determine the volume of a cylinder pipe or hose in gallons?

A

Capacity and gallons equals
n x r² x H (or L’) x 7.5 gallons
Where n Pi = 3.14
R= radius or 1/2 of the diameter in feet
H= average height/depth in feet
7.5= number of gallons per cubic foot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What is the formula for computing smooth bore nozzle discharge for gallons per minute when the nozzle pressure is known?

A

GPMs= 29.7 x d² x √NP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

What is the gpm for a handline at 50 psi 1/2 inch tip?
(Fireground)

A

50 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

How many gpm does a 7/8 inch tip flow on a handline at 50 psi?
(Fireground)

A

150 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

A 1 inch tip size for a handline at 50 psi flows how many gpm?
(Fireground)

A

200

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

What is the theoretical gpm for a 7/8 tip size handline at 50 psi?

A

161 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

What is the theoretical gallons per minute for a 1-in tip size handline at 50 psi?

A

210 gpm

30
Q

How many gallons per minute does an 1 1/4 flow theoretical master stream at 80 psi?

A

415 gpm

31
Q

How many gallons per minute does a 1 3/8 tip flow master stream at 80 psi?
(Theoretical)

A

502 gpm

32
Q

What is the theoretical GPM for 1 1/2 tip master stream at 80 psi?

A

598 GPM

33
Q

What is the theoretical gpms for a master stream at 80 psi and a 1 3/4 tip?

A

814 gpm

34
Q

What is the theoretical GPM for a 2-inch tip on a master stream at 80 PSI?

A

1062 gpm

35
Q

The one inch adjustable gallonage fog nozzle is an adjustable flow nozzle that can be set to deliver _______ - ________ gpm?

A

12-60 gpm

36
Q

The one and a half inch Akron assault nozzle flows how many gallons?

A

175 gpm

37
Q

The two and a half inch Akron fog nozzle is an adjustable flow nozzle that can be set to deliver ______ - ________ gpm?

A

125-250 gpm

38
Q

Master stream fog nozzles have an operating range of ______ to _____ gpm?

A

150-2000 gpm

39
Q

What is the nozzle pressure for a booster reel 1 inch rubber line with an adjustable gallonage fog nozzle that can flow between 12 to 60 gpm?

A

100 psi

40
Q

What is the PSI for forestry hose that comes in 50 and 100 ft sections with a 1 in adjustable gallonage fog nozzle that can flow between 12 to 60 gpms or the 22 gallon per minute red fog nozzle?

A

100 psi

41
Q

At what PSI and gallons per minute does the d-CON shower flow?

A

75 psi
270 gpm

42
Q

How many gallons per minute and at what PSI can you flow a piercing nozzle?

A

100 psi
125 gpm

43
Q

How many gallons a minute and at what PSI is the 2 1/2 inch distributor nozzle flow?

A

250 gpm
100 psi

44
Q

How many gallons per minute at 50 psi does the 1 1/2 inch distributor nozzle flow?

A

95 gpm
50 psi

45
Q

How many gallons per minute and PSI does a 21/2 inch cellar nozzle flow?

A

350 gpm
100 psi

46
Q

How many gallons per minute and at what PSI does a 11/2 inch cellar nozzle flow?

A

160 gpm
100 psi

47
Q

What are the three different types of monitors used in Fairfax county?

A

Fix monitors
Combination monitors
Akron quick attack Mercury monitor

48
Q

Smooth bore nozzle flowing between 500-1000 GPM at 80 psi nozzle pressure is an example of what type of monitor?

A

Combination

49
Q

A fog nozzle flowing between 350-1,250 GPM at 100 PSI nozzle pressure is an example of what type of monitor?

A

Combination

50
Q

Smooth bore nozzle flowing between 500 and 1000 GPM is an example of what type of monitor?

A

Fixed monitor

51
Q

What flows 500 gallons per minute from either the fog or smooth or nozzle?

A

Akron quick attack Mercury monitor

52
Q

What is the maximum inlet pressure for the Mercury monitor?

A

150 psi

53
Q

How many principles govern friction loss and hose and piping?

A

4

54
Q

What is the friction loss coefficient for 3 1/2 in hose?

A

0.34

55
Q

What is the friction loss coefficient for 1 in hose?

A

150

56
Q

What is the formula to figure elevation pressure theoretical?

A

H x 0.434 psi/foot

57
Q

Fairfax county portable foam eductor’s flow 95 to ______ GPM with a discharge pressure of _____ PSI at the eductor?

A

125 gpm
200 psi

58
Q

Portable foam eductor must be placed ______ feet from the pump panel and within ______ feet of the nozzle?

A

50 feet
200 feet

59
Q

The nozzle should be no higher than _______ feet above the eductor?

A

5 feet

60
Q

When being supplied from another source the tank fill valve must be kept in the closed position during operation to prevent the water tank from becoming contaminated with concentrate the intake pressure should not exceed _______ PSI? (Foam)

A

10

61
Q

The husky foam system is capable of injecting foam from 0.1 to 3% with a rated capacity of ______ GPM of foam concentrate at _____ psi?

A

3 gpm
150 psi

62
Q

What does the application consist of for CAFS fire attack?

A

2/3 water and 1/3 air with a foam application rate of 0.3%

63
Q

What is the application for CAFS overhaul and exposure protection?

A

2/3 air 1/3 water with a class A foam application rate of 0.5%

64
Q

To maintain the maximum flow from a pressurized water source such as a fire hydrant add the incoming static pressure to _______ PSI?

A

150

65
Q

What is the friction loss coefficient for two 3-in lines?

A

0.2

66
Q

What is the friction loss coefficient for two 4-in lines?

A

0.05

67
Q

What is the friction loss coefficient for one 4 inch line and one 3 inch line?

A

0.09

68
Q

When drafting put your pressure Governor to _______mode and increase throttle to _____ to _____ RPM?

A

Rpm mode
1000 to 1200 rpm

69
Q

What is the formula for determining smooth bore nozzle reaction?

A

1.57 x d² x NP

70
Q

What is the formula for a fog stream nozzle reaction?

A

.0505 x Q x √NP

71
Q

Any time incoming pressure exceeds _____ PSI the pump shall be operated in pump gear?

A

50 psi