Minimum BAT voltage during preflight battery check
More than 25.5 volts
What charging parameters should you see on the DC electric page after turning all BATs back to ON during the Preflight Battery Check
Less than 60 amps and decreasing w/in 10 seconds of BATs ON
If any of the BATs are 25.5 volts or less OR after 10 seconds you have a battery charging at 60+ amps, what should you do?
By reconnecting the batteries during the testing process, you have already started a charging cycle. Once the charging cycle is complete (BATs disconnected on the DC ELEC pg, approx 20 min) Redo the ELEC Test
Minimum BAT voltage for an APU start on Battery Power?
23.5 Volts
Minimum Hydraulic Qty
Within Green Bands
Minimum Cockpit O2 Press
1,000 psi
Minimum Eng Oil Qty
16 qts. May be less (-900 Only) provided you have an ETOPS PDC, “Service Check”, or “Transit Check”
At what temperature should the Flap Lever be left in conf 1 after landing?
30* C or greater. Prevents nuisance AIR WING LEAK warnings
Minimum Water/Waste Quantities
Waste- “Acceptable Level”
Water- 75% or
Flights > 10 hrs- 100% or
Africa- 100%
Fire Extinguisher
Green Band
Rain Repellant
Green Band