Quality Assurance/Quality Control of Equipment Flashcards
The purpose of the SMPTE test pattern is to :
A. Determine transducer sensitivity
B. Measure penetration
C. Measure axial resolution
D. Measure lateral resolution
E. Aid in the setup and quality assurance of displays and cameras
E. Aid in the setup and quality assurance of displays and cameras
What conclusion can be reached by comparing the rods labeled A and B in this phantom image? Pg 132
A. Lateral resolution has deteriorated with depth
B. Elevational resolution has deteriorated with depth
C. Lateral resolution is best with rods labeled B
D. Axial resolution is best with rods labeled B
A. Lateral resolution has deteriorated with depth
The graphic overlay on this phantom image represents a gray-scale assignment curve. What type of curve is being used? Pg133 #572 A. S-curve B. Root curve C. Linear curve D. Light curve
C. Linear curve
The rods depicted by the arrows in this phantom are used to determine what feature of the machine? pg 133 #573 A. Contrast resolution B. Penetration C. Lateral resolution D. Measurement accuracy E. Axial resolution
E. Axial resolution
In this phantom image, two fluid-filled tubes are present. What type of resolution is being evaluated? Pg 134 #574 A. Axial B. Lateral C. Contrast D. Elevational
D. Elevational
You are using a conventional linear array transducer to image the phantom in the previous question (574 pg133). Why does the tube labeled B contain echoes, whereas the tube labeled A does not?
A. Since axial resolution decreases with depth, artifactual echoes are displayed from above and below the tube
B. The frame rate is too slow to display the deeper tube accurately
C. The slice-thickness resolution at the level of tube B is worse than that at the level of tube A
D. The electronic focusing at the level of tube A is more powerful than that at the level of tube B
C. The slice-thickness resolution at the level of tube B is worse than that at the level of tube A
Which of the following should be regularly checked as a component of a quality control program? A. System penetration B. Image uniformity C. Assurance of electric safety D. Distance measurement accuracy E. All of the above
E. All of the above
What is being measured on the three rods in the center of this image? pg 135 A. Axial Resolution Penetration C. Elevational resolution D. Lateral resolution
D. Lateral resolution
What is meant by the “dead-zone” in performance testing?
A. B-mode penetration distance
B. Level at which ultrasound signal is the same strength as the electronic noise
C. Doppler signal obtained at 90*
D. Doppler penetration distance
E. Distance from the transducer to the first identifiable echo
E. Distance from the transducer to the first identifiable echo
Which of the following describes sensitivity?
A. Ability of the system to detect weak echoes
B. Ability of the system to demonstrate highly reflective interfaces
C. Ability to the system to differentiate between two different structures with slightly varying amplitudes
D. Ability of the system to distinguish between two closely spaced structures parallel to the beam
A. Ability of the system to detect weak echoes
These two phantom images were obtained with maximum gain and acoustic power using two different transducers. What information can be obtained by this comparison ? pg 136
A. Transducer A has less penetration than transducer B
B. Lateral resolution is best with transducer B
C. Axial resolution is best with transducer B
D. B and C only
E. All of the above
A. Transducer A has less penetration than transducer B
String test objects are used to evaluate: A. Contrast resolution B. Axial resolution C. Doppler accuracy D. Elevational resolution
C. Doppler accuracy
A hydrophone measures: A. Acoustic pressure output B. Doppler accuracy C. Penetration D. Contrast resolution
A. Acoustic pressure output
Which best describes the effect of damaged transducer elements in the B-mode image?
A. Dark vertical bands beginning at the top of the image
B. Brightimage
C. Cold transducer
D. Decreased frame rate
A. Dark vertical bands beginning at the top of the image
Transducers should NOT be cleaned with: A. Soap and water B. Ultraviolet light (or radiation) C. An autoclave D. Gas E. Cidex
E. Cidex