qc Flashcards

1
Q

what are the alarm indicators and priorities

A

0- only when amos away from monitor facility
1- WSV interior intrusions and SDI intrusions
2- WSV interior tampers
3- PAS exterior intrusions
4- PAS exterior tampers
6- MF duress alarms, amos to other MF
8- MF tampers, system comm, power and lost system alarm
10- WSV self test
-
priority 1- 1 hr
2- 24 hrs
3 72 hrs/ next duty day

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

4 different user authorization profiles for LPE system?

A

-MFO
-sensor NCO
-system admin
-B-Button

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

what are the procedures when an operator duress occurs?

A

-sensor NCO will be contacted
-TPC in place
-alternate facility becomes primary
-AMOS will occur once duress button is utilized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

how many alarms generate when conducting a WSV self test?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

3 different classifications for alarms?

A

-secure
-procedure
-notify

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

how many utility icons are in the runtime toolbar?

A

12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

how long does the authenticating MF have to respond to the command request?

A

60 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

what are the two tones associated with the LPE console?

A

-standard
-AMOS tones

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

what are the 6 components of the code transfer group?

A

-A/B rekey module
-A/B recode module
-A/B universal release code
-A/B unlock module
-A/B code storage module
-code transfer unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

when would the override dual authentication B-Button command be used?

A

-last resort
dual authentication if:
-comm loss btwn LMF/RMF
-power loss at LMF/RMF
-cable infrastructure failure
-duress

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

at minimum how many alarms must be visible in the alarm monitoring window?

A

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

3 different sensor modes?

A

-secure
-accessed
-maintenance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

what are the MF operators duties and responsibilities on the LPE system?

A

-alarm management
-securing alarms/ PAS’s
-dual authentication

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

if a heartbeat msg is not received how many seconds until each host annunciates comm-loss alarm?

A

6-10 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

how long does each MFO have to acknowledge an alarm?

A

30 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

current displayed alarm events video is identified by what?

A

”#”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

8 components of the monitor indicator group?

A

-cameras
-camera power supply
-circuit breakers
-video display monitor
-VICADS
-keyboard and mouse
-luminaire
-signboard

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

what would cause an operator to receive an AMOS alarm?

A

failure to acknowledge an alarm within 30 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

what are the 5 major WS3 groups?

A

-monitor indicator group
-code transfer group
-console group
-vault control group
-voice communication group

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

what is the voice communications system?
& characteristics

A

provides independent voice communication btwn RMF/LMF and WS3 equipped PAS’s

CHARACTERSTICS
-weather proof phone mounted to each PAS
-phone jack inside for maintenance use
-cannot dial from PAS to PAS
-communication btwn multiple PAS’s goes thru LMF/RMF
-VCS not linked to any other phone system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

what information is required for a pre-notification?

A

-name of pre - announcement official
-date and time of pre note
-location
-name of two members opening vault (A&B) (must b verified on AAAL)
-sole vouching authority
-opening/closing time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

what happens after 3 failed login attempts?

A

-console locks for 1 minute
-“illegal login attempt” alarm annunciates at opposite facility

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

what is the alternate controller and its characteristics?

A

-portable piece of electrical/mechanical equipment used as a backup capability to raise the vault
-commercial power raises in 2.5 minutes
-on backup power raises in 4 hrs

24
Q

helping hand?

A

unclassified up channel report to command post reporting possibly hostile event affecting pl 1-3 resources.

25
Q

covered wagon?

A

unclassified up channel report to HHQ of an actual hostile event affecting pl 1-3 resources.

26
Q

alarms that have video attached but are not currently being displayed are identified by what?

27
Q

6 different ways to acknowledge alarms?

A

-F1 button
-plunger
-graphic display ACK ALL
-graphic display int alarms icon
-text display ACK ALL
-text display utility icon

28
Q

what 8 alarms are suppressed when the vault is placed in WSV OPS mode activate?

A

-battery test fail
-back up power on
-power on operate
-WSV now open
-wall penetration
-cover penetration
-liquid sensor
-shock sensor

29
Q

Bent Spear

A

flag word to notify US national command authorities of an unexpected occurrence involving nuclear wpns that dont fall into
-broken arrow
-empty quiver

30
Q

broken arrow

A

notifies US national command authorities of a nuclear wpn accident, incident or event involving nuclear material that could not create the risk of war.

31
Q

dull sword

A

a nuclear wpn system deficiency in safety or security

32
Q

empty quiver

A

loss, theft, seizure, destruction of a nuclear wpn/ critical component

33
Q

NUCFLASH

A

flag word reporting accidental, unauthorized or unexplained incident involving possible detonation of a nuclear wpn that could create the risk of war

34
Q

what are the RAB badge open areas, and authenticators?

A

4- ABW cp
5-VSA
7-munitions storage area
8- crisis action team (CAT)/emergency OPS center(EOC)
9-command post emergency action cell
11-limited/exclusion area
12-sole vouching authority(SVA)/convoy technical safety advisor(CTSA)
13-MAPA S. restricted area
19-DAPA N. restricted area
-
1-american flag and Turkish flag crossed over left shoulder
2-39 ABW seal over right shoulder
3-transparent pic back bottom right

35
Q

what are the locations for the emergency generators and what bldg/PAS’s do they provide power to?

A

bldg 548 backups 548
bldg 2209 backups 2209
H-2 backups H-1, H-2, H-3
H-5 backups H-4, 5,6,7,8
india PAS have their own backup power
OPS: generator load testing - min 1 hr of full load

36
Q

partial failure

A

minor conditions that don’t create system vulnerability but do detract from system operation

EX: inop surveillance,, inop tamper switches

37
Q

major malfunction

A

1-failure resulting in WSV losing alarm protection allowing intruder to penetrate WSV w/o crossing alarm field
2-loss of RMF/LMF monitoring capability
3-one facility unable to monitor the other

38
Q

catastrophic failure

A

total loss of monitoring capabilities

39
Q

which two malfunctions or failures warrant immediate response not to exceed 1 HR?

A

major and catastrophic

40
Q

what does the PAS prevent?(WS3 concept)

A

-prevents observation of nuclear wpns
-protection from small arms fire/aerial attacks
-protection from harsh weather

41
Q

what document are prsnl verified against during vault OPS?

A

-eal
-aaal
-prp

42
Q

how far will maintenance be separated when being matrixed in?

43
Q

what are the 3 unlock codes and what does each do?

A

universal release code- opens any number of vaults, any number of times, no time delay
mass unlock code- opens multiple vaults, one time, 30 min delay
maintenance unlock code- opens one vault, one time, 30 min delay

44
Q

5 reasons you’d perform an individual vaunt test?

A

-changeover
-directed to by sensor NCO
-termination of maintenance
-termination of vault OP/maintenance
-transfer of power

45
Q

5 reasons to perform equipment performance verification?

A

-changeover
-told to by NCO
-system start up
-maintenance termination
-transfer of power

46
Q

when is RMF activation and for how long?

A

-beginning of each shift
-(min of 1hr)

47
Q

6 components of the vault control group?

A

-shelter control panel
-vault electrical panel
-vault processor
-vault assembly w sensors
-alternate controler
-authentication unit

48
Q

4 components of vault mechanical assembly w sensors?

A

-barrier cover plate
-barrier support
-platform assembly
-line assembly

49
Q

11 components of the console group?

A

-Shelter control panel interface board
-ACK all button
-Desk and desk enclosure
-Duress
-LPE annunciator including VIP/VIP-E
-Equipment enclosure
-UPS enclosure
-Touch screen monitors
-AMOS alarm sounder
-Standard alarm sounder
-Keyboard and mouse w ferrite beads

50
Q

the aaal includes what information?

A

-full name
-rank
-social/dod id #
-type of security clearence
-authorized codes
-PRP status

51
Q

which airlift squadron is authorized to transport nuclear wpns?

A

62nd airlift wing
McCord AFB

52
Q

what does RICE stand for?

A

R- respond
I - ISD
C- containment
E - entry

53
Q

how many transactions will be stored in the administrative messages window?

54
Q

what is the general overview of the WS3 system?

A

-underground WSV
-user and host nation SF
-associated electronic system
-equipment and facilities to secure nuclear wpns
-combined w USA custodian prsnl

55
Q

limited area,
exclustion area?

A

limited- contains one or more exclusion area
exclusion-contains one or more nuclear wpns stored