QA Test Flashcards

1
Q

Responsibilities of a craftsman at a FMA

A

Perform all maintenance IAW the FWP.

If the guidance is incorrect/incomplete/unclear, stop and seek clarification from the work center or shift supervisor.

Ensure qa forms are completed correctly

Sign print date on all qa forms

Ensure TMDE is used properly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Fundamental Rule for all maintenance performed by a QA craftsman

A

Technical specifications must be met at all times

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

C

A

Cleanliness inspection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Q

A

Critical quality control point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

V

A

Verification by craftsman

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

I

A

QAI/NDT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

S

A

Ships force

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

You are performing a controlled job and notice the technical specifications for performing the work cannot be followed. What action do you take?

A

Stop work and notify the LPO/WCS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When is a revision required on a CWP

A
  1. Scope of work changes
  2. Boundary of work changes
  3. Changes in test requirements unless authorized by a DFS
  4. Any change in material requirements which result in a change in testing requirements
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What do you record when using TMDE in the in-process control documentation

A

Type of tool
Range
Serial number
Calibration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Before using a calibrated tool, what do you need to do?

A

Verify calibration is within date
Serial number
Range falls within 20-90% in direction of torque

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Who can make non-technical pen and ink changes to a FWP

A

Lpo/lws supervisor or division officer is responsible for the affective step in FWP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Maintenance procedures may be fully usable in their existing form. The minimum requirements to perform work are

A

Valid MP

Permission to conduct work

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What FME cannot be used

A

Tape

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What are two min qualifications to do work

A

Qas, craftsman

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Who has final opening approval for a cwp

A

Dept. head

17
Q

Actions and documentation of UNSAT conditions

A

Craftsman will report unsat conditions and document the rework on applicable qa form

18
Q

Qa-9

A

Controlled work/sub safe

19
Q

Qa 14

A

Assessments, evaluations, audits

When something goes wrong

20
Q

Qa 17

A

Various testing results

21
Q

Qa 20

A

Welding in process control/ndt record

22
Q

Qa 26

A

Hydrostatic/pneumatic test record

23
Q

Your supervisor tell you that you forgot to sign block 10

A

Ensure block 9 with the test and inspection results are signed

24
Q

What signature do you need to commence shipboard testing

A

Division officer of workcenter

Qao

25
Q

Example of a form containing cleanliness requirements

A

Jfmm, reactor plant manual

26
Q

Who must approve pen and ink changes to qa forms

A

After being signed-qao, qas, qai

Qao or all officers that approved the original was forms

27
Q

What does TMDE stand for

A

Test, measuring, diagnostic equipment