What Items are on the 24hr Checks
Caution/Advisory lights Fire detection: Engine, APU, baggage Stall warning ADC Autofeather Flight compartment door access Boots, props, ref switch, bypass doors, windshield Rudder PCU's
Engine Fire detection test
Fire handle Fault A B Warning tone CWP Warning (check fire detect) Master warning Engine fire push to reset
Aft baggage smoke
Warning tone vent inlet/outlet aft btl arm smoke/extg CWP smoke Master warning
Fwd baggage smoke
fwd btl arm
smoke/extg
CWP smoke
Master warning
APU
Apu panel: fire, fault, fuel valve closed, btl arm, ext switch
CWP: apu caution, check fire detect warning
Master caution
Stall warning
Stick shaker
CWP: Stall syst fail / pusher fail caution lights
ADC test
14,360 29.23 IAS MISMATCH, IAS, ALT VMo 284 IAS 285 Overspeed warning tone CWP: Pitch trim / elevator feel / avionics caution lights SAT -15ºC WTG2 FAIL
Autofeather
“PASSED”
test can be performed twice before mx action
Flight compartment access door
bag door, ckpt door, auto unlk and fail light out
CWP: internal door caution light out
Check auto unlock function of door with FA switch
Boots
18psi +/-3
Manual cycle check for illumination
Fast cycle (60secs, 24sec dwell)
Props
Test function
advisory lights illuminate in cycles
ED oil temp 65º
Wait 30sec before repeating test
Ref switch
Check ED indication “Ref speed increase”
Engine intake doors
OPN/HTR
heater advisory light comes on when temp is <15ºC
Windshield heat
Norm for 5min
CWP: WSHLD CTRL caution light does not illuminate
Rudder PCU’s
Push off RUD 1
CWP: RUD HYD caution light
Rudder travel check
Push on RUD 1
Same check with RUD 2