What is the rated capacity of the Mills Tui? (low pressure)
4000L/min at 1000kPa at a 3m lift.
How many litres of water does the tank hold?
2000L
What is the maximum practical lift when draughting?
7.5m
When does the primer enage?
When delivery pressure below 150kPa
How long can you let the primer run for?
30 seconds
What is the maximum flow capacity of the pump?
6200 L/min
How much B class fuel?
200L
What is the flow rate capacity of the ground monitor?
950 L/min
What is the flow rate capacity of the roof monitor?
600 - 4700 L/min
What is the application rate of foam?
6.5 L/min per m2
When does the thermal relief valve open?
42 degrees Celsius
What is the ground monitor operating pressure?
700kPa
What is the Heavy pumper height?
3.35m
What is the Heavy pumper width?
3.0m (including mirrors)
What is the Heavy pumper length?
8.15m