pump preesure Flashcards
250’ 1 3/4 fog
NP= 50 FL=25+25+12.5=62.5 PDP=112.5
250’ 1 3/4 15/16 TIP
NP=50 FL= 30+30+15=75 PDP= 125
150’ 2 1/2 FOG 150 GPM
NP=100 FL= 5 + 2.5 = 107.5 PDP= 107.5
400’ 4” 1 3/8 tip
NP= 80. 500 GPM FL=5 x4 = 20 APP= 10 PDP = 110
300’ 5” 1 3/4 tip
NP=80 APP = 10 FL= 5x3= 15
PDP = 105
150’ 2 1/2 1 1/4 Tip high rise pack
1 1/4 tip NP=50 FL= 20+10=30 PDP= 80psi
200’ 2 1/2 hook to gated wye with ( 2 )-1 3/4 high rise pack what is the GPM and PDP
GPM= 300 NP= 50 FL 2 1/2= 20+20=40
FL= 1 3/4= 25+12.5 = 37.5 APP = 0 PDP = 127.5
400’ 4” master stream 1 1/2 TIP GPM and PDP
APP= 10 NP= 80 FL = 7 x 4 = 28 GPM = 600 PDP = 118
150’ 1 3/4 with 1/2 TIP GPM and PDP
NP= 50 FL 1 3/4 = 5+2.5 = 7.5 GPM= 55 PDP = 57.5
250’ 1 3/4 Akron fog 180 GPM
NP= 75 FL 1 3/4 = 30 +30+15= 45 NP = 75 PDP= 120
200’ 1 3/4 Akron fog 200 GPM
NP= 100 FL= 35 per 100’ = 70 PDP= 170
300’ 1 3/4 Akron fog 150 GPM
NP= 50 FL = 25+25+25= 75 PDP= 125
REd Line Plus 50’
NP= 50 FL= 25+25+12.5= 62.5 PDP= 112.5
Blue Line Plus 100’
NP= 50 FL= 30+30+30=90 PDP= 140
Blue Line Plus 50’
NP= 50 FL= 30+30+15= 75 PDP= 125