pump preesure Flashcards

1
Q

250’ 1 3/4 fog

A

NP= 50 FL=25+25+12.5=62.5 PDP=112.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

250’ 1 3/4 15/16 TIP

A

NP=50 FL= 30+30+15=75 PDP= 125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

150’ 2 1/2 FOG 150 GPM

A

NP=100 FL= 5 + 2.5 = 107.5 PDP= 107.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

400’ 4” 1 3/8 tip

A

NP= 80. 500 GPM FL=5 x4 = 20 APP= 10 PDP = 110

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

300’ 5” 1 3/4 tip

A

NP=80 APP = 10 FL= 5x3= 15

PDP = 105

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

150’ 2 1/2 1 1/4 Tip high rise pack

A

1 1/4 tip NP=50 FL= 20+10=30 PDP= 80psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

200’ 2 1/2 hook to gated wye with ( 2 )-1 3/4 high rise pack what is the GPM and PDP

A

GPM= 300 NP= 50 FL 2 1/2= 20+20=40

FL= 1 3/4= 25+12.5 = 37.5 APP = 0 PDP = 127.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

400’ 4” master stream 1 1/2 TIP GPM and PDP

A
APP= 10 NP= 80 FL = 7 x 4 = 28  GPM = 600
PDP = 118
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

150’ 1 3/4 with 1/2 TIP GPM and PDP

A

NP= 50 FL 1 3/4 = 5+2.5 = 7.5 GPM= 55 PDP = 57.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

250’ 1 3/4 Akron fog 180 GPM

A

NP= 75 FL 1 3/4 = 30 +30+15= 45 NP = 75 PDP= 120

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

200’ 1 3/4 Akron fog 200 GPM

A

NP= 100 FL= 35 per 100’ = 70 PDP= 170

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

300’ 1 3/4 Akron fog 150 GPM

A

NP= 50 FL = 25+25+25= 75 PDP= 125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

REd Line Plus 50’

A

NP= 50 FL= 25+25+12.5= 62.5 PDP= 112.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Blue Line Plus 100’

A

NP= 50 FL= 30+30+30=90 PDP= 140

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Blue Line Plus 50’

A

NP= 50 FL= 30+30+15= 75 PDP= 125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

1 3/4 100’ 1/2 TIP

A

NP= 50 FL= 5 PDP= 55

15
Q

1 3/4 100’ fog

A

NP= 50 FL= 25 PDP= 75

16
Q

1 3/4 100’ 15/16 TIP

A

NP= 50 FL= 30 PDP= 80

17
Q

400 GPM 2 1/2

A

30

18
Q

ELhart foam Nozzle 200’ 1 3/4 GPM=

A

GPM= 125 NP= 75 FL= 20+20= 40 PDP= 115

19
Q

FOG Nozzle Adjustable Gallonage NP=

A

100