Provers Flashcards

1
Q

If the meter being proved by a conventional pipe prover has a resolution of 1 barrel, what
is the necessary minimum capacity of the prover?

A

Since provers need to be in the 0.01% accuracy this prover would need at least 10000 barrels

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Explain what the electronic meter proving counter counts during a proving run

A

Pulses that are produced by a ball moving through the detectors in the prover

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Explain why it is necessary to flow the measuring fluid through the prover and meter for
a while before performing a proving run.

A

1) Get the prover up to process temperature
2) Ensure prover is full

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the end result of a proving run on a meter and how is it used?

A

A meter factor is derived from the test. This meter factor can be multiplied by the meter’s register to obtain a corrected volume display.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Explain why a small volume prover does not require 10,000 or more counts/pulses from the
meter being proved.

A

Small volume provers use the double chronometry method to calculate the fractional meter count

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Give a typical application for small volume provers, and are they usually a fixed or
portable type device?

A

A portable device that can be used to prove meters in the field

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Explain how a tank prover works

A

Process fluid goes into a tank of known volume and the level is measured. The tank can also be weighed gravimetrically before and after for gravimetric proving.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly