Provers Flashcards
If the meter being proved by a conventional pipe prover has a resolution of 1 barrel, what
is the necessary minimum capacity of the prover?
Since provers need to be in the 0.01% accuracy this prover would need at least 10000 barrels
Explain what the electronic meter proving counter counts during a proving run
Pulses that are produced by a ball moving through the detectors in the prover
Explain why it is necessary to flow the measuring fluid through the prover and meter for
a while before performing a proving run.
1) Get the prover up to process temperature
2) Ensure prover is full
What is the end result of a proving run on a meter and how is it used?
A meter factor is derived from the test. This meter factor can be multiplied by the meter’s register to obtain a corrected volume display.
Explain why a small volume prover does not require 10,000 or more counts/pulses from the
meter being proved.
Small volume provers use the double chronometry method to calculate the fractional meter count
Give a typical application for small volume provers, and are they usually a fixed or
portable type device?
A portable device that can be used to prove meters in the field
Explain how a tank prover works
Process fluid goes into a tank of known volume and the level is measured. The tank can also be weighed gravimetrically before and after for gravimetric proving.