protocol Flashcards

1
Q

dipridamole

A

hold for 24-48 hours, if used with adenosine or regadenoson their half lives are prolonged due to inhibition, very rare to cause AV block

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

adenosine causes av block in

A

7.6%, 2nd degree 4% and complete <1 %

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Presence of 2nd/3rd degree of SSS

A

contraindication to adenosine, regadenoson or dipyridamole

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Rest or pharm stress wait

A

30 mins - 60 mins for hepatobiliary activity to clear

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

exercise stress wait

A

10-15 mins minimal hepatobiliary activity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

if you scan and stomach or intestine too hot

A

have pt drink water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

liver to hot on scan or intestine

A

wait

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

prone positioning can cause

A

artifactual anteroseptal defect 2/2 to increased sternal attenuation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

acquisition time supine vs prone

A

reduced in prone by 20-40%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Acquisition energy window w/in

A

20% so for Tc99 126-154

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Simultaneous protocol images are acquired

A

at the same time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

simultaneous protocol images injection

A

inject with thalium normal 3-4 millicuries, stress with low dose of Tc99

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

motion artifact

A

creates a hurrican effect which MC correct for but only in vertical plane (horizontal and rotational motion cant be corrected)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Ramp filter

A

seen during filtered back projection uaing a ramp filter we get loss of counts in adjacent myocardial walls

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

ring artifacts

A

seen with nonuniformity across the camera head (check by daily floods)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

skewed artifacts

A

error in COR cause misregistration

17
Q

whats minimum peak pixel count in LV for Tc 99on planar spect

A

200count/pixel

18
Q

whats minimum peak pixel count in LV for thalium on planar spect

A

100 count/pixel

19
Q

Counts in myocardium influenced by

A

body habitus/mass index, Level of exercise of pharm stresss, administered dose or radiopharmaceutical, acquistion time energy window and type of collimator

20
Q

TID is caused by

A

3vessel or microvessel disease

21
Q

number of recommended projections for Tc99

A

60-65 (related to optimal resolution of imaging system)- higher resoluion than thalium

22
Q

number of recommended projections for Thalium

A

lower resolution so 32 are acceptable

23
Q

when preforming SPECT thalium 201 we get home many different energy peaks to help max counts

A

3 help to reduce radiation dose

24
Q

probability of specific type of interaction is baed on

A

number of protons (Z number) and energy of proton

25
Butterworth filter
is a way of adhancing signal to noise ration, So to make image les noisy you increase the power factor
26
difference between X ray vs gamma ray as source
X ray is not discrete but is rather range of energy depending on electron shell. which negatively impact image quality
27
radionuclude impurity
the presence of 99MO in a 99TC is considered
28
further the positron travels before annilation the ____ to the image
the worse the image because less ability for spatial resolution
29
photoelectoron tubes work by
light striking the photocathode which is negatively charged. low energy electrons are ejected when light stikes which of the following
30
Transient equilibrium is
99MO/99Tc
31
secular equilibrium
Rhobidium and strontium
32
isomeric transition of technesium result in
only the energy state of on nucleon changes. Positrons are given off when a proton changes into a neurtron in positron decay
33
characteristic radiation
given off when electron gives off energy as it moves to fill a vacancy by another electron being ejected through internal conversion
34
multiple pinhole collimators causes
increase sensitivity and spatial resolution during SPECT
35
99Mo/99Tc the max 99Tc is obtained how many hours after the last elution of 99Tc
24 hours