Prof Prac Flashcards
Under rule 2, when is the building is exempted from building permit requirement?
Public buildings, traditional family dwellings - used by one family constructed in native materials, total cost of which is less than Php 15,000.00
If tower, spires, and steeples, is made of combustible materials, what is the height limit projections?
6.0 meter above BHL
Under rule 3 of PD 1096, when is thw building permit exempted?
Minor construction, repair works, minor structures of 6sqm or less detached from other building, for private use only
What is the maximum available height (in meters) for building for C2?
18 m
When is the building permit expires? Under what scenarios.
Construction does not commence within 1 year from date of issuance
What are the building types under the Fire Zone 1 or Non - Fire retricted zones?
Residential, educational institutional, Assembly, small business and retail mercantile buildings.
How many years does is the accountability of an engineer or an architect upon completion of a building?
15 years
Under what type of occupancies, this refer to building for non-leasing occupants not exceeding 10 persons?
A-2
A type of occupancy in which the building is used for school or day-care purposes not classified in Group H and I occupancies
Occupancy Type C
For Mezzanine floors what is the minimum clear ceiling height?
1.80 m
What is the minimum width of stairs under PD 1096?
750 mm
Parking Slot - Standard parking slot for perpendicular parking for a car
2.50 m x 5.00 m
What does UTS stands for
Utilities, Transportation, Services
Article _____ of the civil code that states the liability of an Engineer and Architect dew up the plans and specification
Article 1723
In PD 1096, it is a minimum width of the door
900 mm
What is the minimum riser and tread in PD 1096?
200 mm x200 mm
What is the minimum standard of eaves from property line?
750mm
In R5, what is the maximum allowable firewall for two sides?
Maximum of 75% total should not exceed 50% of lot perimeter
What is the minimum dimension is required by NBC for kitchens?
1.50m
For R4, Two sides what is the maximum allowable firewall?
85% of each side
In NBC R1 property, what is the standard front setbacks?
4.50m
Parking Slot - Standard parking slot for parallel parking for a car
2.15m x 6.00m
For R5 : one side + rear, what is the maximum allowable firewalls for side and rear?
65% of side and 50% of rear
Minimum ceiling height required for the kitchen
2.70m
In PD 1096, what is the minimum hieght of doors?
2.00m
What is the occupant load prescribed by NBC for kitchens?
18.60 sqm / person
What is the minimum width of corridor in PD 1096?
1.10m
Under educational, what is the standard occupant load for a class room per person
1.80 sqm
What is the maximum travel distance to an exit, with no splinker?
45m
Usually expressed in the form of a time period rating (how lonf a material can withstand being burned)
FIRE RESISTIVE RATING
What is the standard occupant load per person for a place of assembly
0.65sqm
What is the standard handrail height in NBC?
800-900mm
What is the minimum ceiling height in GF level with naturally ventilated?
2.70m
Under light and ventilation, what is the minimum dimension of court?
2.00m
For offices and factories what is the minimum air space requirements?
12.00 cubic meter
In a public hospital parking requirement, 1 car slot for every?
25 beds
In a public universities parking requirement, 1 car slot for every
5 classrooms
Hotel parking requirement, if highly urbanized
1 slot for every 3 rooms
For 6-7m width of RROW what is the BHL?
9.00m or 3 storey
For 4-5 width of RROW what is the BHL
7.5m or 2.5 storey
What type of occupancies, wher no work is done except exchange of parts, maintainance without open flame, welding or highly flammable liquids
Group E: Business + Mercantile
Under rule 6, Fire resistive standards, what is the minimum thickness for 4HR solid pre-stressed concrete slab - over all depth
150mm
A secondary structure located within the same premises, the use of which is incidental to that of the main building/structure
Ancillary building/structure
Buildings in multiple fire zone = shall be considered as part of the more restrictive zone if _____ is in that zone.
more than 1/3 of its TFA
Does garden masonry walls with 1.50m in height considered as minor construction?
No
Construction in a building involving changes in materials used, partitioning, location/size of openings, structural parts, existing utilities and equipments but does not increase the overall area thereof
Alteration
Any physical change in a building to increase its value, utility, or to improve its aesthetic quality
Renovation
Remedial work done on any damage or deteriorated portions of a structure to restore its original condition
Repair
A change in the use or occupancy of a building or any portions thereof which has different requirement
Conversion
The systematic dismantling or destruction of a building in whole or in part
Demolition
Under Rule 2, unauthorized deviation from the drawings during construction is considered as prohibited acts
True
A written authorization granted by the Building Official to an applicant allowing him to proceed with construction after plans, specifications and other pertinent documents have been found to be in conformity wirh the Code
Building Permit
What is TGFA
Total Gross Floor Area
AMVB
Allowable maximum volume of building
OFB
Outer faces of the building
FLAR
Floor and Lot Area Ratio
In strucural loads, what is the first floor live load?
200kg/sqm
In structural loads, what is its second live load?
150kg/sqm
In structural loads, what is the wind load for roofs?
120kg/sqm (vertical)
In hotels, of not highly urbanized
1 slot for every 2 rooms
Sample parking requirements in hotels
-2 tourist bus parking slots
-1 loading slot for aticulated truck
-If highly urbanized, 1 slot for every 3 rooms
-if not, 1 slot for every 2 rooms
SAMPLE PARKING REQUIREMENT (Public Hospital)
-1 car slot for every 25 bed
-1 loading space for 2 jeepney/shuttle slots
-1 slot for articulated truck
-1 slot for standard truck for every 5,000 sqm gross area
-Add truck maneuvering space outside RROW
In churches, for every 50 sqm. of congregation area, provide:
-1 car slot
-1 jeepney slot
Parking reqs. in Public Universities
-1 car slot for every 5 classrooms
-1 loading space for 2 jeepney or shuttle slots
-1 school bus for every 200 students
For RROW width of 9.00m or more, the minimum sidewalk width shall be
1.20m on each side of the RROW
RROW ABOVE GRADE, minimum clear height
4.27m from crown of carriageway
Parking Slot - standard parking slot for Jeepney
3.00m x 9.00m
Parking Slot sizes - standard truck/bus
3.60m x 12.00m