PROCESS CONTROL & INSTRUMENTATION - INDIABIX Flashcards

1
Q

Which of the following is an undesirable dynamic characteristic of an instrument ?

A

Time lag

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which of the following is not the triple point of water ?

A

32°R

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Pick out the one which is a first order instrument.
A. Mercury in glass thermometer (without any covering or air gap).
B. Bare metallic thermometer.
C. Bare vapor pressure thermometer.
D. All (a), (b) and (c).

A

All (a), (b) and (c).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Load cells are used for the measurement of

A

Weight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which of the following is the dynamic characteristics of an instrument ?

A

Fidelity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Pick out the wrong statement.
A. O2, NO and NO2 exhibit paramagnetic properties as a result of unpaired electrons.
B. CO2 is the strongest paramagnetic gas.
C. Paramagnetic susceptibility of gases decreases with temperature.
D. Paramagnetic susceptibility of gases permits the measurement of their concentration.

A

CO2 is the strongest paramagnetic gas.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The __________ of a vapor pressure thermometer is a functioning element.

A

Pointer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A negative gain margin expressed in decibels means a/an __________ system.

A

Unstable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Thermistor, which has high temperature co-efficient of resistivity, is used as the sensing element in resistance thermometer. It is a/an

A

solid semi-conductor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Flapper nozzle is used in a/an __________ controller.

A

pneumatic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Typical specifications for design stipulates the gain margin and phase margin to be respectively

A

> 1.7 and > 30°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Working principle of radiation pyrometer is based on the

A

Stefan-Boltzman law

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which of the following relates the emf. generated in a single homogeneous wire to the temperature difference ?

A

Thomson effect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Dilute wine was used as a thermometric liquid initially to develop temperature scale. First emperical temperature scale developed was the __________ scale.

A

Fahrenheit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

In a single tank system, the transfer function of level to inlet flow rate is

A

R/(TS + 1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Which of the following is a desirable characteristic of an instrument ?

A

High fidelity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

The operation of a rotameter is based on

A

Variable flow area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

The temperature of tempering oil baths maintained at 400°C during heat treatment of steel is measured by a/an __________ thermocouple.

A

iron-constantan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Instrumentation in a plant offers the advantage of
A. greater safety of operation
B. better quality of product
C. greater operation economy
D. all (a), (b) and (c)

A

All (a), (b) and (c)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Which of the following temperature measuring instruments need not touch the object whose temperature is being measured ?

A

Radiation/infrared pyrometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Thermal conductivity measurement comprises the working principle of a

A

CO2 analyser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Response of a system to a sinusoidal input is called __________ response.

A

frequency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

The closed loop pole of a stable second order system could be

A

both real and negative

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Smoke density of the flue gas going out of the chimney is measured by a

A

photo electric cell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Transfer function of transportation lag is

A

e^-TS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Temperature measuring instruments are standardised mostly with __________ points of pure substances.

A. melting
B. boiling
C. both (a) & (b)
D. neither (a) nor (b)

A

both (a) & (b)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Pick out the first order system from among the following.

A. Damped vibrator.
B. Mercury in glass thermometer kept in boiling water.
C. Interacting system of two tanks in series.
D. Non-interacting system of two tanks in series.

A

Mercury in glass thermometer kept in boiling water.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

The maximum service temperature for fibre glass used as thermocouple wire insulation material is __________ °C.

A

500

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

Which of the following controllers has the least maximum deviation ?

A. P-controller
B. P-I controller
C. P-I-D controller
D. P-D controller

A

P-D controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

Volumetric expansion is the working principle of the __________ thermometers

A

mercury in glass

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

Which of the following measurements can be made by the measurement of emf?

A. pH value
B. Degree of hydrolysis
C. Composition of complex ions
D. All (a), (b) & (c)

A

All (a), (b) & (c)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

A magnetic flowmeter is

A. based on the principle of Faraday’s law.
B. capable of measuring the flow rate of slurries and electrolytes.
C. based on the linear relationship between the fluid flow rate and the induced voltage.
D. all (a), (b) and (c).

A

all (a), (b) and (c)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Zirconia probe is used for the continuous measurment of __________ flue gases going out of the furnace.

A

oxygen in

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

Strain gage pressure transducers are used to measure __________ pressures.

A. gage as well as vacuum
B. absolute as well as differential
C. both (a) and (b)
D. neither (a) nor (b)

A

both (a) and (b)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

Compositional analysis of __________ is done using mass spectrometer.

A

an isotope

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

The function of a transducer is to

A

convert the primary signal into a more useful quantity, usually an electric impulse

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

Nichol’s chart deals with

A

closed loop values vs. open loop values

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

Which of the following thermocouples will give the highest output for the same value of hot and cold junction temperature?

A

Chromel-constantan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

A proportional controller with a gain of Kc is used to control a first order process. The offset will increase, if

A

Kc is reduced

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

__________ is undesirable in thermocouples used in industries,

A

Non-linear relation of emf to temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

Select the correct statement from the following.

A. The frequency response of a pure capacity process is unbounded.
B. The phase lag of a pure time delay system decreases with increasing frequency.
C. The amplitude ratio of a pure capacity process is inversely proportional to frequency.
D. The amplitude ratio of a pure time delay system increases with frequency.

A

The amplitude ratio of a pure capacity process is inversely proportional to frequency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

For an input forcing function, X(t) = 2t^2, the Laplace transform of this function is

A

4/s^3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

Continuous shell temperature measurement in a liquid-liquid heat exchanger is done by a

A

thermocouple

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
44
Q

The __________ of a vapor pressure thermometer is a secondary element.

A

Bourdon tube

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
45
Q

Emf developed by a thermocouple, while measuring a temperature of 600°C is about 5.5 mV. The type of thermocouple used is

A

platinum-platinum+rhodium

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
46
Q

Which of the following relates the absorption & evolution of heat at the junctions of a thermocouple to the current flow in the circuit?

A

Peltier effect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
47
Q

In a shell and tube heat exchanger, the flow rate of heating/cooling fluid is the __________ variable.

A

manipulated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
48
Q

A non-linear chemical system is exemplified by a/an

A

non-isothermal CSTR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
49
Q

The frequency response of a first order system, has a phase shift with lower and upper bounds given by

A

0, π/2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
50
Q

Gas chromatography is used for the measurement of

A

concentration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
51
Q

Which of the following thermocouples can measure the maximum temperature ?

A

Tungsten-molybdenum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
52
Q

Radiation pyrometers as compared to thermocouples

A

can measure higher temperature.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
53
Q

Liquid flow rate in a small channel is best measured by a/an

A

pitot tube

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
54
Q

Specific gravity of a liquid can not be measured by a/an

A

anemometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
55
Q

__________ temperature scale assigns 0° to the ‘ice point’ and 80° to the ‘steam point’.

A

Reumur

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
56
Q

Dead zone is the

A

maximum change in the variable that does not change the reading of the instrument.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
57
Q

Which of the following thermometers is not suitable for distant reading up to 60 meters?

A

Mercury in glass thermometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
58
Q

Degree to which an instrument indicates the changes in measured variable without dynamic error is called its

A

fidielity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
59
Q

Thermistors are made of

A

metal oxides

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
60
Q

A barometer measures the __________ pressure.

A

absolute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
61
Q

Humidity of air can be determined by a

A

sling psychrometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
62
Q

Thermocouple in a thermal well behaves as a true

A

multiple first order system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
63
Q

The transfer function for a P-D controller is

A

Kc(1+τD s)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
64
Q

Bode diagram is a plot of

A

log (AR) vs. log (f) and (Φ) vs. log (f)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
65
Q

Working principle of disappearing filament type optical pyrometer is based on the

A

Wien’s law

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
66
Q

Strain gage uses an electrical conductor wire, which when elastically stretched increases in length and reduces in diameter. Both these dimensional changes result in __________ in the electrical resistance of the wire.

A

increase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
67
Q

Pick out the wrong statement

A. Proportional controller is normally used for level control in industrial applications.
B. CSTR can be considered as a distributed parameter system.
C. Distributed parameter approach gives partial differential equation.
D. Non-linear behaviour is exemplified by an on-off controller.

A

CSTR can be considered as a distributed parameter system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
68
Q

Range of hydrogen gas constant volume themometer is __________ °C.

A

0 to 100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
69
Q

The initial value (t=0) of the unit step response of the transfer function [(s + 1)/(2s + 1)] is

A

1/2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
70
Q

The __________ of a vapor pressure thermometer is a primary element.

A

bulb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
71
Q

The time constant of a first order process with resistance R and capacitance C is

A

RC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
72
Q

A sinusoidal variation in the input passing through a linear first order system

A

gets attenuated (magnitude decreases).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
73
Q

Nitrogen gas constant volume thermometer is suitable for measuring a temperature of __________ °C.

A

> 100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
74
Q

Pick out the most suitable instrument for measuring temperature in the range of-40 to 425°C.

A. mercury thermometer
B. bimetallic thermometer
C. radiation pyrometer
D. none of these

A

bimetallic thermometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
75
Q

Accurate temperature measurement performance of a radiation pyrometer can not be affected, if the

A

object and surrounding are at almost the same temperature.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
76
Q

Relationship between absorption/evolution of heat at the thermocouple junctions and the current flow in the circuit is given by __________ effect.

A

Peltier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
77
Q

Configuration of Bourdon spring tube is never made of __________ shape.

A

Circular

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
78
Q

Thermodynamic celcius scale of temperature measurement is

A. defined on the basis of melting point of ice and evaporation temperature of water vapor.
B. defined on the basis of melting point of ice and condensation temperature of water vapor.
C. having an interval of 100° between ice point to steam point.
D. both (b) and (c)

A

both (b) and (c)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
79
Q

According to Bode stability criterian, a system is unstable, if the open loop frequency response exhibits an amplitude ratio exceeding unity at frequency for which phase lag is

A

180°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
80
Q

In a closed loop system, the process to be controlled is an integrating process with transfer function l/2s. The controller proposed to be used in an integral controller with transfer function 1/T1s. When a step change in set point is applied to such a closed loop system, the controlled variable will exhibit

A

underdamped response.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
81
Q

Resistance of a gas in a vessel is given by (where, P = pressure, V = volume of the vessel, n = no. of moles of the gas, R = gas constant)

A

V/nRT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
82
Q

Measurement of pressure in ammonia reactor is done by

A

Bourdon gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
83
Q

The fluid used in hydraulic controller is
water

A

oil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
84
Q

Flow rate of a river is measured by a/an

A

vane meter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
85
Q

Which of the following thermocouple materials does not contain nickel?

A. Alumel
B. Chromel
C. Constantan
D. None of these.

A

None of these.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
86
Q

Flow rate of those fluids which are insensitive to changes in their density, viscosity or flow velocity profile can be best measured by a

A

magnetic flowmeter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
87
Q

Identify an unbounded input from inputs whose transfer functions are given below

A

1/S^2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
88
Q

“A control system is unstable, if the open loop frequency response exhibits an amplitude ratio exceeding unity at the crossover frequency.” This is __________ criterion.

A

Bode stability

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
89
Q

Feed forward controller accounts for the __________ changes.

A

load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
90
Q

Which thermocouple can be used to measure a temperature of around 1400°C ?

A. Copper-constantan
B. Aluminium-chromel
C. Platinum-platinum+rhodium
D. None of these

A

Platinum-platinum+rhodium

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
91
Q

Which of the following filled system expansion thermometer has the capability to measure the lowest temperature ?

A

Alcohol in glass thermometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
92
Q

Concentration of sugar solution can be determined by the

A

polarimetry

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
93
Q

In a single tank system, the transfer function of __________ to inlet flow rate is 1/TS+1.

A

outlet flow rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
94
Q

Which of the following can not measure a temperature of 1600°C ?

A

Platinum resistance thermometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
95
Q

The temperature range for which copper resistance thermometer can be used is __________ °C

A

-200 to 150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
96
Q

Paramagnetism method is not used for the composition determination of __________ in gases.

A

carbon dioxide

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
97
Q

An amplitude ratio of 0.1 corresponds to __________ decibels.

A

-20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
98
Q

For increased speed of response of an expansion pressure spring thermometer, the thermometer bulb should have a

A. large area but small mass.
B. high thermal conductivity.
C. small specific heat.
D. all’a’, ‘b’ & ‘c’.

A

all’a’, ‘b’ & ‘c’.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
99
Q

Pressure of 0.0001 absolute psi can be measured by __________ gauge.

A

Mcloid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
100
Q

Pirani gauge is used for the measurement of

A

high vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
101
Q

The __________ of the fluid contained in the temperature sensing element (i.e., bulb) of filled system thermometers changes with change in temperature.

A. pressure
B. volume
C. viscosity
D. all (a), (b) and (c)

A

all (a), (b) and (c)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
102
Q

The characteristic equation for the control system with a closed loop transfer function G1/1 + G2 is given by 1 + G2 = 0. The characteristic equation for the control system

A. depends only upon the open loop transfer function.
B. determines its stability.
C. is the same for set point or load changes.
D. all ‘a’, ‘b’ & ‘c’

A

all ‘a’, ‘b’ & ‘c’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
103
Q

__________ thermometer can not measure sub-zero (< 0° C) temperature,
Mercury in glass

A

Bimetallic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
104
Q

Starting temperature of optical radiation pyrometer is __________ °C

A

800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
105
Q

Liquid argon level in a pressurised storage tank (at 3 kg/cm^2 ) is measured by a/an

A

differential pressure gage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
106
Q

Which of the systems having following transfer functions is stable?

A

1/(s^2 + 2s + 2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
107
Q

What is the dynamic error in a critically damped second order instrument for a ramp input (At) ?

A

2 AT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
108
Q

The deflection of the free end of the bimetallic strips in a bimetallic thermometer with temperature is nearly

A

linear

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
109
Q

Alphatron measures pressure __________ microns.
< 1

A

> 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
110
Q

What is the ratio of output amplitude to input amplitude for a sinusoidal forcing function in a first order system ?

A

< 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
111
Q

The term analogous to the electrical current in a thermal system is the

A

heat flow rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
112
Q

Reset rate is the another term used for __________ time.

A

integral

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
113
Q

Continuous measurement of moisture in paper is done by

A

high resistance Wheatstone’s bridge circuit.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
114
Q

Psychrometer determines the

A

humidity of gases

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
115
Q

A mercury barometer measures the __________ pressure.

A

atmospheric

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
116
Q

Positioning controllers are used for

A

high loads

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
117
Q

The amplitude ratio for the sinusoidal response of a __________ is 1.

A

transportation lag

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
118
Q

The response of two tanks of same size and resistance in series is

A

critically damped

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
119
Q

The amplitude ratio for the sinusoidal response of __________ is < 1.

A

first order system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
120
Q

Which of the following is a ‘contact’ pyrometer ?

A

resistance pyrometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
121
Q

Which of the following is not a speed measuring instrument?

A

Psychrometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
122
Q

Measurement of sub-zero Celcius temperature in industry is done most commonly by

A

resistance thermometers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
123
Q

Use of I-control along with P-control facilitates

A

elimination of offset

124
Q

Turbine flow meters are suitable for

A

both (b) and (c)

125
Q

Liquid discharge from a tank or reservoir can not be measured by

A

orificemeters

126
Q

Which of the following is not a mechanical pressure sensing element?

A

U-tube

127
Q

__________ are analysed using a polarograph.

A

Solids

128
Q

Which of the following judges the accuracy of an instrument?

A

Static error

129
Q

On-off controllers are normally used for

A

Low loads

130
Q

Magnetic flowmeters are generally not used for the velocity/flow measurement of hydrocarbons due to their

A

low electrical conductivity

131
Q

Which of the following controllers has maximum offset ?

A. P-controller
B. P-I controller
C. P-D controller
D. P-I-D controller

A

P-controller

132
Q

Pressure of 0.01 psi (absolute) can be measured by __________ gauge.

A

Mcloid

133
Q

High temperature of around 2000°C of incandescent gas mantles is measured by a/an

A

radiation pyrometer

134
Q

The unit step response of the transfer function 1/(s^2 + 2s + 3)

A

has a damped oscillatory characteristics

135
Q

The time constant of a unity gain, first order plus time delay process is 5 min. If the phase lag at a frequency of 0.2 rad/min is 60°, then the dead time (in minutes) is

A

5π/12

136
Q

Which of the following does not figure in the list of seven substances selected for international temperature scale ?

A. Ice (F.P) and steam (B.P)
B. Oxygen and sulphur (B.P)
C. Antimony and silver (F.P)
D. Zinc (B.P) and mercury (F.P)

A

Zinc (B.P) and mercury (F.P)

137
Q

A constant volume gas thermometer employing __________ is used to measure sub-zero (i.e., < 0° C) temperature.

A

helium

138
Q

pH meter has

A

two cells

139
Q

Routh test

A

cannot be used to test the stability of a control system containing transportation lag

140
Q

When a bare thermocouple is covered by a protective sheath, the response becomes

A

slower and non-oscillatory

141
Q

What is the normal percentage of rhodium in platinum + rhodium element used in the thermocouple?

A

13

142
Q

Helium gas constant volume thermometer is suitable for the measurement of a temperature of __________ °C.

A

< 0

143
Q

Bode diagram are generated from output response of the system subjected to which of the following input?

A

Sinusoidal

144
Q

Which of the following thermocouples is the most suitable for measuring a temperature of about 1600°C in an oxidizing atmosphere?

A

Platinum-platinum + rhodium

145
Q

Mercury thermometer can be used to measure the temperature up to __________ °C.

A

350

146
Q

Vapour actuated pressure spring thermometer does not require ambient temperature compensation. Ambient temperature compensation is provided in gas or liquid expansion pressure spring thermometer by

A. making the volume of thermometer bulb as large as conveniently possible.
B. reducing the volume of the capillary to a minimum.
C. reducing the volume of the receiving element to a minimum.
D. all ‘a’, ‘b’ & ‘c’

A

all ‘a’, ‘b’ & ‘c’

147
Q

Which of the following is not a differential pressure flow meter?

A

Rotameter

148
Q

Working principle of mercury in glass thermometer is based on volumetric expansion of mercury with increase in temperature. Which of the following undergoes minimum volumetric expansion for a given temperature change ?

A

Mercury

149
Q

Bourdon gauges are used for measuring pressure (kg/cm^2 )

A

> 2 (gauge)

150
Q

A photo electric device in which the resistance of the metal is directly proportional to the light striking on it, is known as photo-conductive cell. Photoelectric transducers are used for the measurement of those parameters, which can be used to produce variation in

A

light intensity

151
Q

A typical example of a physical system with under damped characteristic is a

A

spring loaded diaphragm valve

152
Q

An aneroid barometer measures the __________ pressure.

A

absolute

153
Q

A bolometer is

A. used for the measurement of thermal radiation.
B. an element which senses optical input and delivers thermal output.
C. both (a) & (b).
D. neither (a) nor (b).

A

both (a) & (b)

154
Q

Thermal wells are used in the temperature measurement to

A

guard against corrosive and oxidising action on thermocouple materials

155
Q

The offset introduced by proportional controller with gain Kc in response of first order system can be reduced by

A

introducing integral control.

156
Q

A system with a double pole at the origin is unstable since the corresponding term in the time domain

A

grows linearly with time.

157
Q

To increase the speed of response of a pressure spring liquid or gas expansion thermometer, the clearance space between the thermometer bulb and the thermal well should not be filled with

A

air

158
Q

In a second order under damped system, the

A

overshoot (which is a measure of how much the response exceeds the ultimate value) increase with the decrease of damping co-efficient e

159
Q

In an exothermic chemical reactor, the manipulated variable is the flow rate of

A

coolant

160
Q

Very low pressure is expressed in microns(μ), which is equal to __________ mm of Hg coloumn (absolute) at 0°C.

A

0.001

161
Q

Thermal conductivity based continuous flue gas analyser makes use of varying thermal conductivity of the constituents of flue gases. Which of the following constituents of flue gases has the maximum thermal conductivity ?

A

CO2

162
Q

Emf generated in a thermocouple depends on the temperature

A

difference between hot and cold junctions

163
Q

Working principle of mercury in glass thermometer is based on the __________ of mercury with increase in temperature.

A

volumetric expansion

164
Q

Radiation thermometer can not measure the temperature

A

of liquid oxygen.

165
Q

Temperature measurement by optical pyrometer is done above __________ point, which is 1063°C.
gold

A

gold

166
Q

Continuous flue gas analyser makes use of paramagnetic properties of some of its constituents, which move towards the strongest part of the magnetic field thus displacing diamagnetic gases. Which of the following gases is diamagnetic ?

A

CO2

167
Q

Dilatometer is used to measure

A

contraction/expansion due to changes in temperature

168
Q

Mass spectrometer is used for the composition analysis of

A

isotopes

169
Q

A first order system with a time constant of 1 min is subjected to frequency response analysis. At an input frequency of 1 radian/min, the phase shift is

A

-45°

170
Q

__________ stability method uses open loop transfer function.

A

Nyquist

171
Q

A pyranometer is an instrument used for measuring the

A

global radiation

172
Q

All the thermocouples used for temperature measurement use dissimilar metal

A

wires

173
Q

Composition of alloys can be determined by

A

polarograph

174
Q

Optical activity of a solution can be determined using a

A

polarimeter

175
Q

Stability of a control system containing a transportation lag can be best analysed by

A

frequency response methods

176
Q

Stabilising time for the controllers is the time required for the response to reach __________ percent of its ultimate value.

A

95

177
Q

Time constant is the

A

time taken by the controlled variable to reach 63.2% of its full change.

178
Q

Mercury manometer (U-tube type) exemplifies a __________ order system

A

second

179
Q

Emf developed by a thermocouple while measuring a temperature of 400°C is 22 mV. The type of thermocouple used is

A

iron-constantan

180
Q

Bode stability method uses __________ loop transfer function

A

open

181
Q

Working principle of bimetallic thermometers is difference in linear co-efficient of thermal expansion of two strips of different metals welded together. Which of the following has the maximum thermal co-efficient of linear expansion?

A

Brass

182
Q

Which of the following is not a second order instrument ?

A

Bare mercury in glass thermometer.

183
Q

Small furnace draught is accurately measured by an inclined tube manometer, in which the manometric liquid used most commonly is

A

paraffin

184
Q

Specific conductance is defined as the reciprocal of resistance in ohms of 1c.c. of liquid at a specified temperature. Its value for distilled water is about __________ micro mho/cm^3.

A

1

185
Q

A simple pitot tube measures the

A

static pressure

186
Q

For a feed back control system to be stable, the

A

poles of the closed loop transfer function should lie in the left half of the complex plane

187
Q

A mercury thermometer can not be used to measure the temperature below the freezing point of mercury, which is __________ °C.

A

-38.9

188
Q

__________ controller has the maximum stabilising time.

A

PI

189
Q

Out of the following temperature measuring instruments, the measurement accuracy will be minimum for the

A

optical pyrometer

190
Q

Stalagmometer is used for the measurement of

A

surface tension

191
Q

The deflection in diaphragm (which is used as pressure sensor in pneumatic and electronic instruments) is dependent on the metal thickness, its diameter (d) and shape & number of corrugations. Its deflection is proportional to

A

d^4

192
Q

Working principle of radiation pyrometer is based on the

A

Stefan-Boltzman law

193
Q

Liquid levels in autocalves are measued by

A

differential float type manometer

194
Q

E.m.f. generated by thermocouples is of the order of

A

millivolts

195
Q

A pyrheliometer is an instrument used for measuring the

A

beam radiation

196
Q

Flow rate through an orifice is __________ the pressure differential.

A

proportional to the square root of

197
Q

Thermistors are used in __________ devices.

A. voltage measuring
B. temperature measuring
C. temperature compensating
D. both(b)&(c)

A

both (b) & (c)

198
Q

__________ is the static characteristics of an instrument,

A

Drift

199
Q

Phase lag of the frequency response of a second order system to a sinusoidal forcing function

A

approaches 180° asymptotically

200
Q

Dead zone in an instrument must be less than __________ percent of the scale.

A

0.2

201
Q

Emission spectroscopy is used for

A

solids and metal analysis.

202
Q

Gas analysis is commonly done using the

A

thermal conductivity cell

203
Q

Thermal conductivity measurement is used for the determination of

A

CO2 percentage in the flue gas.

204
Q

Presence of a small amount of water in the organic systems can be determined by the __________ method.

A

dielectric constant end loss factor

205
Q

Thermal conductivity cell is the primary element of a/an __________ analyser.

A

carbon dioxide

206
Q

Zirconia probe is used for the measurement of

A

% O2 in flue gas.

207
Q

The root locus method, a pole of a transfer function G(s) is the value of s for which G(s) approaches

A

208
Q

__________ type of element is normally not used in the bimetallic thermometers.

A

Bourdon tube

209
Q

Suppose that the gain, time constant and dead time of a process with the following transfer function: Gc(s) = 10 exp( - 0.1s)/(0.5s + 1) are known with a possible error of ± 20% of their values. The largest permissible gain Kc of a proportional controller needs to be calculated below taking the values of process gain, time constant and dead time as

A

12, 0.6, 0.12

210
Q

Process degree of freedom indicates __________ number of controllers to be used.

A

the maximum

211
Q

Characteristic equation is the denominator of __________ loop transfer function.

A

closed

211
Q

Operating range of a temperature measuring instrument is 800 to 1600°C. It could be a/an __________ pyrometer.

A

photoelectric

211
Q

Polarograph is meant for the analysis of

A

solids

212
Q

Which of the following fluid flow measuring devices can measure the largest flow rate ?

A

Weir

212
Q

Flow rate of sludge is not measured by a/an

A. orificemeter
B. open weir
C. kennison nozzle
D. both (b) & (c)

A

both (b) & (c)

212
Q

In a shell and tube heat exchanger, the inlet temperature of heating/cooling fluid is the __________ variable

A

load

212
Q

A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same

A. temperature measuring range (- 40°C to 450°C).
B. accuracy (± 1% of span).
C. speed of response.
D. all a, b & c.

A

all a, b & c.

213
Q

Thermal wells used in temperature measurements should have

A

high transmissivity of radiation.

214
Q

Which of the following flow-metering instruments is an area meter ?

A

rotameter

214
Q

Out of the following themocouple wire insulating material, the highest temperature rating is for

A

ceramic fibre

215
Q

Which is the most suitable instrument for measuring pressure below 3 microns ?

A

Ionisation gauge

216
Q

Routh stability method uses __________ loop transfer function.

A

closed

217
Q

Pyrometry refers to the measurement of temperature

A

which is of higher magnitude.

218
Q

Photoelectric pyrometers are suitable in the temperature range of __________ °C.

A

800 - 1600

219
Q

Non-metallic diaphragm used as pressure sensor in instruments is generally made of

A

synthetic rubber

220
Q

Response of a linear control system for a change in set point is called

A

servo problem

221
Q

Hot wire anemometer is used for the measurement of

A

flow rates of fluids.

222
Q

Which of the following thermocouples has the widest temperature measurement range ?

A

Platinum-platinum/rhodium

223
Q

Temperature control of an exothermic chemical reaction taking place in a CSTR is done with the help of cooling water flowing in a jacket around the reactor. The types of valve and controller action to be recommended are

A

air to open valve with the controller indirect acting

224
Q

Bourdon tube is never made of

A

cast iron

225
Q

“An emf of the order of mV is generated when two solutions of different hydrogen ion concentration are separated by a thin glass wall”. This is the working principle of a

A

pH meter

226
Q

The term analogous to voltage in a single tank system is the

A

level of liquid

227
Q

In a shell and tube heat exchanger, the outlet temperature of heating/cooling fluid is the __________ variable.

A

controlled

228
Q

Mcleoid gauge is used to measure the

A

vacuum

229
Q

What is the Laplace transform of impulse input having magnitude ‘X’ ?

A

1

230
Q

Thermocouple is suitable for measuring

A

both high and low temperatures

231
Q

Bimetal strips are not used in

A

thermocouples

232
Q

When the damping co-efficient (ξ) is unity, the system is

A

critically damped

233
Q

Nickel percentage in invar which is an iron-nickel alloy, and is used as a thermocouple material is

A

36

234
Q

Silver point temperature is __________ °C.

A

960.5

235
Q

A non-linear system will have __________ steady state values.

A

more than one

236
Q

Which of the following is not a variable area flow meter ?

A

Magnetic flow meter

237
Q

With increase in temperature, the electrical conductivity of the platinum used in the resistance thermometer

A

decreases

238
Q

Sub-zero temperature (< 0°C) can be measured by a constant volume gas thermometer employing

A

helium

239
Q

__________ is an example of distributed parameter system

A

tubular reactor

240
Q

Which of the following is not classified as a thermo electric pyrometer ?

A

Optical pyrometer (disappearing filament type)

241
Q

Maximum differential pressure in liquid manometer is __________ psi.

A

30

242
Q

Phase margin is equal to

A

180° - phase lag

243
Q

Flow rate measurement of hostile acids and alkalis can be most suitably done by a/an

A

magnetic flow meter

244
Q

Compositional analysis of flue gas coming out of a furnace in respect of O2 and CO2% can be continuously done by a/an

A

thermal conductivity cell

245
Q

Thermisters which have a very high temperature co-efficient of resistivity belong to the class of solid called

A

semi conductors

246
Q

The pressure sensing element of elastic type pressure gauge is never made in the form of a

A

strip

247
Q

Liquid flow rate in an open channel can not be measured by a/an

A

orifice meter

248
Q

The unit of ‘time constant’ of a system is the same as that of

A

time

249
Q

Which of the following filled system expansion thermometers has the lowest positive temperature measurement capability ?

A

Alcohol in glass thermometer

250
Q

Liquid column manometers are used for measuring the pressure __________ kgf/cm^2 .

A

< 3 (gage)

251
Q

Cascade control means

A

more than one feed-back loop

252
Q

The level of a liquid under pressure can be determined using

A

differential pressure manometer

253
Q

Temperature measurement range of iron-constantan thermocouple is 0 to 870°C. It can be used to measure sub zero temperature, because at lower temperature

A. emf produced is very low of the order of microvolt.
B. embrittlement of iron occurs.
C. rusting of iron takes place.
D. both (b) and (c).

A

both (b) and (c)

254
Q

Which of the following is never used as an element of industrial resistance thermometer ?

A

lead

255
Q

Which of the following shows maximum dip effect (indicating reverse direction of temperature change) ?

A

Mercury thermometer

256
Q

A stable system is the one

A

for which the output response is bounded for all bounded input.

257
Q

The Laplace transform of exp(at), where a > 0, is defined only for the Laplace parameter, s > a since

A

the Laplace transform of integral of exp(at) has finite values only for s > a.

258
Q

Meleoid gauge measures the __________ pressure.

A

sub-atmospheric

259
Q

Which of the following thermocouples is capable of measuring a temperature of -50°C?

A

Platinum - platinum + rhodium

260
Q

Platinum resistance thermometer can be used up to antimony point which is __________ °C, and is the temperature of equilibrium between solid antimony & liquid antimony at normal atmospheric pressure.

A

630.74

261
Q

Which of the following instruments is not used for measuring sub-zero (<0°) temperatures ?

A

Radiation pyrometer

261
Q

Change of angle of refraction with composition comprises the working principle of a

A

refractrometer

262
Q

Which of the following is not suitable for measuring the temperature of a red hot object in the range of 800 - 1600°C?

A

Thermocouples

263
Q

Flame photometry is used for the determination of compositional analysis of

A

alkali metals

264
Q

Reference points i.e., ice point and steam point in Reaumer temperature scale are respectively

A

0° & 80°

265
Q

Which of the following is not a composition measuring instrument ?

A. Thermal conductivity cell
B. Mass spectrometer
C. Polarograph
D. Hot wire anemometer

A

Hot wire anemometer

266
Q

Emf developed by a thermocouple while measuring a temperature of 800°C is about 31 mV. The type of thermocouple used is

A

chromel-alumel

267
Q

Which of the following thermocouples is incapable of measuring sub-zero (i.e., < 0°C) temperature?

A

Platinum-platinum + rhodium

268
Q

Platinum resistance thermometer is the international standard for temperature measurement between

A. triple point of hydrogen and freezing point of antimony
B. 13.81°K to 903.9°K
C. both (a) and (b)
D. neither (a) nor (b)

A

both (a) and (b)

269
Q

On-off control which is a special case of proportional control, has a band width of about __________ percent.

A

0

270
Q

The thermal emf-temperature relationship of most thermocouples is

A

parabolic

270
Q

In Bode plot, A.R. vs. w is plotted on a/an __________ graph paper.

A

log-lag

270
Q

Which is the strongest paramagnetic gas?

A

O2

271
Q

Continuous measurement of specific gravity of a liquid is done by

A. hydrometer
B. contact-type electric indicators
C. displacement meter
D. both (a) and (c)

A

both (a) and (c)

271
Q

A first order system with unity gain and time constant τ is subjected to a sinusoidal input of frequency w = 1/τ. The amplitude ratio for this system is

A

1/sqrt(2)

271
Q

For measuring the temperature of a red hot furnace, which is the most suitable instrument ?

A

Optical pyrometer

271
Q

Stroboscope is used for the measurement of

A

rpm of a flywheel

272
Q

In second order underdamped system,

A

decay ratio = (overshoot)^2

273
Q

Dome temperature of blast furnace stove is most accurately measured by a

A

platinum-platinum/rhodium thermocouple

274
Q

Phase lag of the sinusoidal response of a first order system is

A

90°

275
Q

Continuous measurement of moisture content of paper in paper industry is done by measuring the

A

electrical resistance through the paper

276
Q

Thermal well made of __________ gives the fastest speed of response, while measuring temperature by thermocouples.

A

vycor (a glass)

277
Q

Pick out the wrong statement.

A. There is no transfer lag for a single first order system.
B. Stirred tank with a water jacket exemplifies an interacting system.
C. Transfer lag is a characteristics of all higher order systems (other than first order systems).
D. Transfer lag decreases as the number of stages decreases.

A

Transfer lag decreases as the number of stages decreases.

278
Q

Working principle of mercury in glass thermometer is

A

volumetric expansion

279
Q

The frequency at which maximum amplitude ratio is attained is called the __________ frequency.

A

resonant

280
Q

Which of the following can measure temperatures in the range of - 20 to 300°C ?

A. Mercury in glass thermometer
B. Vapor pressure thermometer
C. Resistance thermometer
D. None of these.

A

None of these.

281
Q

If response of a control system is to be free of offset and oscillation, the most suitable controller is

A

proportional integral-derivative (PID) controller

282
Q

Conversion formula for converting amplitude ratio (AR) into decibels is

A

Decibel = 20 log10 (AR)

283
Q

Normal mercury thermometer can be used to measure a temperature of about 300°C. However, its maximum temperature measurement range can be increased up to about 500°C by

A

filling nitrogen under pressure in the stem

283
Q

A manometer measures the __________ pressure.

A

gauge

283
Q

Minute depression of freezing point of a liquid solvent on addition of a solid solute can be best measured by a

A

Beckman thermometer

284
Q

Temperature of __________ can not be measured by an optical or radiation pyrometer.

A

hot blast (air) from stoves

284
Q

Gain margin is equal to the

A

reciprocal of amplitude ratio

284
Q

In Bode plot, Φ vs ω is plotted on a/an __________ graph paper.

A

log-log

285
Q

Temperature of molten pig iron (1450°C) and molten slag (1500°C) flowing out of a blast furnace is measured by a/an

A. chromel-alumel thermocouple
B. optical pyrometer
C. radiation pyrometer
D. either (b) or (c)

A

either (b) or (c)

286
Q

For two non-interacting first order systems connected in series, the overall transfer function is the __________ of the individual transfer functions.

A

product

287
Q

Mercury thermometer is commonly used for low temperature measurement. The freezing point and boiling point of mercury are respectively __________ °C.

A

-39 and 350

287
Q

Ordinary mercury in glass thermometer is used for measuring temperature up to 120°C. However, for measuring higher temperature up to __________ °C, thermometer is made by filling nitrogen under pressure above the mercury, which stops the evaporation of mercury and reduces the chance of broken thread of mercury.

A

550

288
Q

Composition of natural gas is determined by the

A. Haldane apparatus
B. mass spectrometer
C. chromatograph
D. both (b) and (c)

A

both (b) and (c)

289
Q

Which of the following thermocouples has the least temperature measurement range?

A

Copper-constantan