Process Control and Instrumentation Flashcards

(53 cards)

1
Q

The maximum service temperature for fibre glass used as thermocouple wire insulation material is __________ °C.

A

500°C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which of the following thermocouples will give the highest output for the same value of hot and cold junction temperature ?

A

Chromel-constantan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Continuous shell temperature measurement in a liquid-liquid heat exchanger is done by a

A

thermocouple

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The frequency response of a first order system, has a phase shift with lower and upper bounds given by

A

0, π/2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The transfer function for a P-D controller is

A

Kc(1+τD s)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Pick out the most suitable instrument for measuring temperature in the range of -40 to 425°C.

A

bimetallic thermometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Relationship between absorption/evolution of heat at the thermocouple junctions and the current flow in the circuit is given by __________ effect.

A

Peltier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Measurement of pressure in ammonia reactor is done by

A

Bourdon gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The temperature range for which copper resistance thermometer can be used is __________ °C

A

-200 to 150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Pirani gauge is used for the measurement of

A

high vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

__________ thermometer can not measure sub-zero (< 0° C) temperature.

A

Bimetallic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Starting temperature of optical radiation pyrometer is __________ °C.

A

800

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The deflection of the free end of the bimetallic strips in a bimetallic thermometer with temperature is nearly

A

linear

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Measurement of sub-zero Celcius temperature in industry is done most commonly by

A

resistance thermometers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which of the following is not a mechanical pressure sensing element?

A

U-tube

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Which of the following judges the accuracy of an instrument?

A

Static error

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

High temperature of around 2000°C of incandescent gas mantles is measured by a/an

A

radiation pyrometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

he unit step response of the transfer function 1/(s2 + 2s + 3)

A

has a damped oscillatory characteristics

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the normal percentage of rhodium in platinum + rhodium element used in the thermocouple?

A

13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

The transfer function of a process is 1/(16s2 + 8s + 4). If a step change is introduced into the system, then the response will be

A

under damped

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

An aneroid barometer measures the __________ pressure.

A

absolute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Thermal conductivity based continuous flue gas analyser makes use of varying thermal conductivity of the constituents of flue gases. Which of the following constituents of flue gases has the maximum thermal conductivity?

23
Q

Dilatometer is used to measure

A

contraction/expansion due to changes in temperature

24
Q

__________ stability method uses open loop transfer function.

25
Composition of alloys can be determined by
polarograph
26
Emf developed by a thermocouple while measuring a temperature of 400°C is 22 mV. The type of thermocouple used is
iron-constantan
27
Out of the following temperature measuring instruments, the measurement accuracy will be minimum for the
optical pyrometer
28
The deflection in diaphragm (which is used as pressure sensor in pneumatic and electronic instruments) is dependent on the metal thickness, its diameter (d) and shape & number of corrugations. Its deflection is proportional to
d^4
29
Gas analysis is commonly done using the
thermal conductivity cell
30
Thermal conductivity measurement is used for the determination of
CO2 percentage in the flue gas
31
Process degree of freedom indicates __________ number of controllers to be used.
maximum
32
Which of the following flow-metering instruments is an areameter?
Rotameter
33
Which is the most suitable instrument for measuring pressure below 3 microns?
Ionisation gauge
34
Bourdon tube is never made of
cast iron
35
Flow rate measurement of hostile acids and alkalis can be most suitably done by a/an
magnetic flow meter
36
Which of the following instruments is not used for measuring sub-zero (<0°) temperatures ?
Radiation pyrometer
37
Emf developed by a thermocouple while measuring a temperature of 800°C is about 31 mV. The type of thermocouple used is
chromel-alumel
38
Which of the following thermocouples is incapable of measuring sub-zero (i.e., < 0°C) temperature ?
Platinum-platinum + rhodium
39
A first order system with unity gain and time constant τ is subjected to a sinusoidal input of frequency w = 1/τ. The amplitude ratio for this system is
1/(2^1/2)
40
Dome temperature of blast furnace stove is most accurately measured by a
platinum-platinum/rhodium thermocouple
41
Which of the following can measure temperatures in the range of - 20 to 300°C?
none of these
42
"A control system is unstable, if the open loop frequency response exhibits an amplitude ratio exceeding unity at the crossover frequency." This is __________ criterion.
Bode stability
43
Positioning controllers are used for
high loads
44
High temperature of around 2000°C of incandescent gas mantles is measured by a/an
radiation pyrometer
45
Stabilising time for the controllers is the time required for the response to reach __________ percent of its ultimate value.
95
46
__________ controller has the maximum stabilising time.
PI
47
Emission spectroscopy is used for
solids and metal analysis
48
Operating range of a temperature measuring instrument is 800 to 1600°C. It could be a/an __________ pyrometer.
photoelectric
49
In a shell and tube heat exchanger, the inlet temperature of heating/cooling fluid is the __________ variable.
load
50
In a shell and tube heat exchanger, the outlet temperature of heating/cooling fluid is the __________ variable.
controlled
51
What is the Laplace transform of impulse input having magnitude 'X' ?
1
52
Which of the following filled system expansion thermometers has the lowest positive temperature measurement capability ?
Alcohol in glass thermometer.
53
Which of the following is not suitable for measuring the temperature of a red hot object in the range of 800 - 1600°C ?
thermocouples