Pick out the one which is a first order instrument.
All (a), (b) and (c)
Load cells are used for the measurement of
Weight
Which of the following is the dynamic characteristics of an instrument ?
Fidelity
Pick out the wrong statement.
CO2 is the strongest paramagnetic gas.
The __________ of a vapor pressure thermometer is a functioning element.
Pointer
A negative gain margin expressed in decibels means a/an __________ system.
Unstable
Thermistor, which has high temperature co-efficient of resistivity, is used as the sensing element in resistance thermometer. It is a/an
solid semi-conductor
Flapper nozzle is used in a/an __________ controller.
pneumatic
Typical specifications for design stipulates the gain margin and phase margin to be respectively
> 1.7 and > 30°
Working principle of radiation pyrometer is based on the
Stafan-Boltzman law
Which of the following relates the emf. generated in a single homogeneous wire to the temperature difference ?
Thomson effect
Dilute wine was used as a thermometric liquid initially to develop temperature scale. First emperical temperature scale developed was the __________ scale.
Fahrenheit
In a single tank system, the transfer function of level to inlet flow rate is
R/(TS + 1)
Which of the following is a desirable characteristic of an instrument ?
High fidelity
The operation of a rotameter is based on
variable flow area
The temperature of tempering oil baths maintained at 400°C during heat treatment of steel is measured by a/an __________ thermocouple.
iron-constantan
Instrumentation in a plant offers the advantage of
all (a), (b) and (c)
(greater safety of operation
better quality of product
greater operation economy)
Which of the following temperature measuring instruments need not touch the object whose temperature is being measured ?
Radiation/infrared pyrometer
Thermal conductivity measurement com-prises the working principle of a _________.
CO2 analyser
Response of a system to a sinusoidal input is called __________ response.
frequency
The closed loop pole of a stable second order system could be
both real and negative.
Smoke density of the flue gas going out of the chimney is measured by a
photo electric cell
Transfer function of transportation lag is
e-TS
Temperature measuring instruments are standardised mostly with __________ points of pure substances.
both (a) & (b)
(melting
boiling)
Pick out the first order system from among the following.
Mercury in glass thermometer kept in boiling water.
The maximum service temperature for fibre glass used as thermocouple wire insulation material is __________ °C.
500 °C
Which of the following controllers has the least maximum deviation ?
P-D controller
Volumetric expansion is the working principle of the __________ thermometers.
mercury in glass
A magnetic flowmeter is
all (a), (b) and (c)
Zirconia probe is used for the continuous measurment of __________ flue gases going out of the furnace.
oxygen in
Strain gage pressure transducers are used to measure __________ pressures.
both (a) and (b)
(gage as well as vacuum
absolute as well as differential)
The transfer function for a PID controller is (where, τ i is the integral (reset) time and τD is the derivative time.)
Kc(1 + 1/τis + τD. s)
Compositional analysis of __________ is done using mass spectrometer.
an isotope
The function of a transducer is to
convert the primary signal into a more useful quantity, usually an electric impulse.
Nichol’s chart deals with
closed loop values vs. open loop values
Which of the following thermocouples will give the highest output for the same value of hot and cold junction temperature ?
Chromel-constantan
A proportional controller with a gain of Kc is used to control a first order process. The offset will increase, if
Kc is reduced
The symbol for “capillary line” in instrumentation diagram is
————-——
__________ is undesirable in thermocouples used in industries,
Non-linear relation of emf to temperature
Select the correct statement from the following.
The amplitude ratio of a pure capacity process is inversely proportional to frequency.
Continuous shell temperature measurement in a liquid-liquid heat exchanger is done by a
thermocouple
The __________ of a vapor pressure thermometer is a secondary element.
Bourdon tube
Emf developed by a thermocouple, while measuring a temperature of 600°C is about 5.5 mV. The type of thermocouple used is
platinum-platinum+rhodium
Which of the following relates the absorption & evolution of heat at the junctions of a thermocouple to the current flow in the circuit?
Peltier effect
The second order system with the transfer function has a damping ratio of
In a shell and tube heat exchanger, the flow rate of heating/cooling fluid is the __________ variable.
manipulated
The second order system with the transfer function has a damping ratio of
0.5
A non-linear chemical system is exemplified by a/an
non-isothermal CSTR
The transfer function for an ideal proportional plus reset controller (reset time T) is
Kc(1 + 1/TS)
The frequency response of a first order system, has a phase shift with lower and upper bounds given by
0, π/2
Gas chromatography is used for the measurement of
concentration
Which of the following thermocouples can measure the maximum temperature ?
Tungsten-molybdenum
Radiation pyrometers as compared to thermocouples
can measure higher temperature