In a wide line cape, The presence of dormers in the front increases the chances of having second-floor bedrooms the easiest access to the second floor is via portable ladders on exposures ……
2 and 4 side
A queen and can be 2 1/2 to 3 1/2 stories in height, have a width of 25 to 30 feet and a depth of 30 to 50 feet, it may have a sprinklered hallway and/or a fire escape. A narrow Staircase in the side or rear will connect which floors ?
- First, second and third
- Or from the first floor directly to the third
The absence of a window in a decorative peek at a private dwelling may indicate the presence of a……
Flat roof
In a ranch style private dwelling the kitchen, living room and bedrooms are all located on the…….
First floor
In a split level private dwelling, one side of the house may have a garage and the bedrooms are located……
Above the garage
In private dwellings open lightweight construction with the absence of a sheet rock ceiling will lead to…….
Early collapse
The lack of windows on the side of a private dwelling with a second entrance and a stoop is indicative of a possible…..
Second floor apartment, with the only entrance on that side of the house.
Many fires in private dwellings originate in the…..
Cellar
LONG ANSWER
Indications of fire in the cellar of a private dwelling are?
1 Fire or smoke pushing from cellar window
2 Smoke pushing from the chimney especially during summer months
3 High heat and heavy smoke with no visible fire on the first floor
4 Very hard floor boards or smoke showing from baseboards
5 smoke from attic windows or louvered vents Especially in older homes with balloon frame construction
In private dwellings, When entering the first floor main entrance above cellar fire with thermal imaging camera and it is showing heat waves emanating across the ceiling or smoke showing significant force and speed under pressure will indicate……
Interior cellar door is open
The incident commander( chief or company officer) Can order an exterior line operated through a cellar window at a private dwelling to allow for a quick knock down when……
There will be a delay applying water through the interior
The incident commander should order the immediate operation of a hose line into a cellar window of a private dwelling in an emergency such as…..
1 Members trapped by fire in cellar
2 Members endangered by Fire because collapse has occurred
The quickest option for cellar fires in detached or semi attached private Dwellings is usually….
The secondary entrance
The quickest option for cellar fires in attached private dwelling’s is usually
Through the front door
In private dwelling fires, Bilco doors should be used for cellar fires if it is….
The only option
Reasons that would preclude the dissent of first hose line down interior stairs are …….
1 High heat
2 Questionability of stairs
3 Serious fire condition
In a cellar fire of a private dwelling, Once the first hose line is in place on the first floor, the decision to reposition the hose line can only be made by the …….
Acting chief or chief
At a private dwelling fires a 2 1/2 inch hose line should also be considered when encountering…..
1 Wind impacted fire
2 Heavily involved first floor fire in a larger style private dwelling( Queen Anne)