Private Dwellings Flashcards

1
Q

In a wide line cape, The presence of dormers in the front increases the chances of having second-floor bedrooms the easiest access to the second floor is via portable ladders on exposures ……

A

2 and 4 side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A queen and can be 2 1/2 to 3 1/2 stories in height, have a width of 25 to 30 feet and a depth of 30 to 50 feet, it may have a sprinklered hallway and/or a fire escape. A narrow Staircase in the side or rear will connect which floors ?

A
  • First, second and third

- Or from the first floor directly to the third

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The absence of a window in a decorative peek at a private dwelling may indicate the presence of a……

A

Flat roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In a ranch style private dwelling the kitchen, living room and bedrooms are all located on the…….

A

First floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In a split level private dwelling, one side of the house may have a garage and the bedrooms are located……

A

Above the garage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

In private dwellings open lightweight construction with the absence of a sheet rock ceiling will lead to…….

A

Early collapse

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The lack of windows on the side of a private dwelling with a second entrance and a stoop is indicative of a possible…..

A

Second floor apartment, with the only entrance on that side of the house.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Many fires in private dwellings originate in the…..

A

Cellar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

LONG ANSWER

Indications of fire in the cellar of a private dwelling are?

A

1 Fire or smoke pushing from cellar window

2 Smoke pushing from the chimney especially during summer months

3 High heat and heavy smoke with no visible fire on the first floor

4 Very hard floor boards or smoke showing from baseboards

5 smoke from attic windows or louvered vents Especially in older homes with balloon frame construction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

In private dwellings, When entering the first floor main entrance above cellar fire with thermal imaging camera and it is showing heat waves emanating across the ceiling or smoke showing significant force and speed under pressure will indicate……

A

Interior cellar door is open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The incident commander( chief or company officer) Can order an exterior line operated through a cellar window at a private dwelling to allow for a quick knock down when……

A

There will be a delay applying water through the interior

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The incident commander should order the immediate operation of a hose line into a cellar window of a private dwelling in an emergency such as…..

A

1 Members trapped by fire in cellar

2 Members endangered by Fire because collapse has occurred

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The quickest option for cellar fires in detached or semi attached private Dwellings is usually….

A

The secondary entrance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The quickest option for cellar fires in attached private dwelling’s is usually

A

Through the front door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

In private dwelling fires, Bilco doors should be used for cellar fires if it is….

A

The only option

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Reasons that would preclude the dissent of first hose line down interior stairs are …….

A

1 High heat

2 Questionability of stairs

3 Serious fire condition

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

In a cellar fire of a private dwelling, Once the first hose line is in place on the first floor, the decision to reposition the hose line can only be made by the …….

A

Acting chief or chief

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

At a private dwelling fires a 2 1/2 inch hose line should also be considered when encountering…..

A

1 Wind impacted fire

2 Heavily involved first floor fire in a larger style private dwelling( Queen Anne)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Private dwellings may have limited space between them

At ground level The distance can be?

At roof level the distance can be?

A

Ground - 6 - 8 ft.

Roof level - 2 - 3 ft.

20
Q

Load bearing or not loadbearing

Tail Beam?

Trimmer beam?

A

Tail beam - not load-bearing

Trimmer beam - Load bearing

21
Q

Who’s responsibility is it to shut down utilities at a private dwelling fire?

A

2nd due trick

22
Q

At private dwelling fires When the first due roof/ov team in a tower ladder is operating in a bucket the second due roof/ ov team of the 2nd Tower ladder should….

A

Operate with portable ladders on upper floors

23
Q

When possible, at a peeked roof private dwelling, the preferred position of the tower ladder is parallel to the front of the building so that the basket can be placed……

A

Over the corner of the building near the peak of the roof

24
Q

The initial vent hole at a peeked roof private dwelling should be made at the ?

A

Main gable

25
Q

When ventilating a peaked roof of a private dwelling a power saw may be used from a……

A

Tower ladder basket ONLY

26
Q

The order of preference for access to flat roof Private dwelling is:

A Scissor ladder can be used to gain access to a flat roof in a private dwelling if the buildings are attached however if the adjoining building is made of wood frame then the

A

1 Aerial ladder

2 Tower ladder

3 Portable ladder

Immediate attached private Dwelling should not be used

27
Q

Before descending stairs at a cellar fire in a private dwelling the first due inside team should….

A

Conduct a primary search of the first floor

28
Q

Members opening knee walls in the attic should avoid opening walls near the….

A

Stairs

29
Q

If it is necessary to operate a hose line into the attic from the floor below, the truck should open up a hole that is what dimension?

If wood is encountered while attempting to open this hole this may be indicative of a cat walk and a new hole should be opened how many feet from the original hole?

A

3 ft wide

3 ft to one side

30
Q

In a private dwelling fire if there is no ceiling to provide protection to the Joists, collapse can occur in ?

A

20 mins

31
Q

The primary consideration in buildings with lightweight construction is

A

Collapse

32
Q

In private dwellings, Areas unsupported by columns with spans greater than 25 feet are generally indications that……

A

Light weight construction is present

33
Q

In private dwellings, the most common type of peaked roof lightweight construction is the…….

A

Open Web light weight wood trust

34
Q

In the construction of light weight private dwellings, The New York City building code requires lightweight constructed spaces between the ceiling and floor above to be…..

A

500 square feet or less

- Unless equipped with an automatic sprinkler system

35
Q

In private dwellings, when using lightweight parallel cord trusses, the connections will be how deep into the wooden truss member ?

A

1/4 “ to 1/2 “ Into the wooden trust member

36
Q

In private dwellings, when using lightweight parallel cord truss construction, and the weakest point of the support system is the…..

A

Gang nails

37
Q

In private dwellings laminated wood I beams may spend lengths over…….

A

60 ft

38
Q

When talking about laminated wood I beams, a fire retardant material sprayed on the beam will dry out over time making it brittle and……

A

Further reduce its strength

39
Q

In private dwellings, a much greater potential for Backdraft may occur in the truss loft,
or attic/cockloft area when the open web design of which two light weight construction supports are used ?

A

Light weight parallel cord wood or composite trusses

40
Q

In private dwellings, The primary emphasis for a fire in a lightweight building, under construction is an exterior attack unless……

A

The fire is minor or contained to a small area

41
Q

In private dwellings, the presence of smoke pushing at the floor line, outside of the building may be an indication of a……….

A

Trussloft

42
Q

For a fire in a building constructed of lightweight material the incident commander should special call …….

A

An extra engine

43
Q

An outside operation in a private dwelling with lightweight construction must be considered when the fire is of such magnitude and can not be knocked down with how many hose lines?

A

2 Handlines

44
Q

The preferred method for advancing the hose line at private dwelling fires with light weight construction is the……

A

Leg forward method

45
Q

The roof of a private dwelling with lightweight construction shall be cut when?

A

Never

46
Q

If there is no fire in the cockloft of a private dwelling with lightweight construction, roof members will not be cutting the roof, But they can still perform the following duties…..

A

1 Check rear and sides of building

2 Vent top floor windows and skylights

3 Inspect HVAC duct vents for unusual heat

After completion of duties on roof the members shall be removed from roof

47
Q

The key size up indicators for the incident commander at a fire for a private dwelling with lightweight construction include……

A

E L V S

1 Extent of fire

2 Location of fire

3 Volume of smoke and fire

4 Smoke action