Practice Questions Flashcards

1
Q

Method of protection against backflow at point of the change of jurisdiction over water.

A

Containment Protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the installation criteria for an SVB assembly?

A

12” above downstream plumbing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the installation criteria for a PVB assembly?

A

12” above downstream plumbing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the installation criteria for an RP assembly?

A

12” above ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

PVB and SVB assemblies are designed to protect against what kind of backflow.

A

Back siphonage only (indirect cross connections)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which assembly protects against low degree/non-health risks only?

A

DC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A dual check device is designed with what components?

A

Two check valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A hose bibb vacuum breaker (HBVB) device is designed with what components?

A

One check valve and one atmospheric vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

An Atmospheric vacuum Breaker (AVB) device is designed with what components?

A

One piece air inlet valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A Dual Check with atmospheric vent devices is designed with what components?

A

Two check valves, One atmospheric vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which backflow preventer device is allowed on landscape irrigation systems?

A

AVB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The risk of thermal expansion is significantly increased when the water system installs which backflow preventer?

A

Dual Check

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

List all the backflow preventer devices that provide a high degree/ health hazard protection

A

HBVB, AVB, Deck-mounted vacuum breaker, Air gap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

List all processes that are categorized as high / health hazard.

A

Landscape irrigation, Pressurized irrigation, Privately owned well, Ethylene glycol fire suppression, Wastewater connection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which authority states that the water systems are responsible to protect the quality of water to the last free flowing tap?

A

1974 Safe Drinking Water Act and the 1996 Amendments.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How many feet of water can be lifted at sea level with a perfect vacuum?

A

33.9’

17
Q

A column of water 23.1 feet produces how much pressure

A

10 PSI
(2.31 feet of head = 1 PSI)

18
Q

What happens to the water when it flows through a constricted area of piping, known as a venturi?

A

Velocity increases and pressure decreases

19
Q

List all the cross connections which utilize an aspirator

A
  1. Landscape chemigation for fertilizers using a venturi and water pump,
  2. Chemical dispenser for cleaning supplies using a venturi and water pump
  3. Pesticide applicator connected to a garden hose
20
Q

List which are direct cross connections (back siphonage and back pressure)

A
  1. Landscape chemigation for fertilizers using a venturi and water pump
  2. Chemical dispenser for cleaning supplies using a venturi and water pump
21
Q

Barometric loops are legal in Utah (T/F)

A

False

22
Q

A pressurized irrigation line is not allowed to be installed in the same trench as a culinary water line. (T/F)

A

True

23
Q

IPC states a PVB can be installed on a landscape irrigation system for backflow protection. However, a local authority statement may state PVB assemblies are not allowed on landscape irrigation systems. (T/F)

A

True