Tooke gauge non universal, what is the standard used
ASTM 4138 - measurement of dry film thickness of protective coating systems by destructive means (method A)
Took gauge measurements range(s) for 1x
1 mil reticle and 20-100 mils max range
Took gauge measurements range(s) for 2x
.5mil reticle and 3-20mil max range
Tooke gauge measurements range(s) for 10x
0.1mil reticle and 0-3mils max range
what dft gauge can be used for non metal coatings and substrate
UT-DFT gauge
What standard is used for UT-DFT gauge?
ASTM D6132 - standard test method for nondestructive measurement of dry film thickness of applied organic coatings using an ultrasonic gauge
What is the standard method for Pull-off Adhesion testing
ASTM D 4541 - standard Test method for pull off strength of coatings using portable adhesion testers
Adhesion testing- what does cohesion failure mean?
Failure within a coating layer (the one coating itself failed) a,b,c,d, etc
Adhesion testing- what does adhesion failure mean?
by the interfaces at which they occur, A/B, B/C, C/D, etc (whole coat fail to another or substrate
Adhesion testing- max allotted time for continuous pressure?
100 seconds
What is eddy-current DFT gauge used for
Non-ferrous metals- Aluminum, copper, Brass, and stainless steel.
What standard is used for eddy-current DFT gauges?
SSPC-PA 2
What standard should be used for barcol impressor?
ASTM D 2583, standard test method for indentation hardness or rigid plastic by means of barcol impressor
What does a test with barcol impressor tell you
Indication of cure
How to field verify calibration of barcol impressor?
Hard and soft alloy disks and glass disk given reading of 100.