Powerplant Limitations Flashcards

1
Q

ITT Limits (Starting)

A
  • 800 and Below = No time limit
  • 801 - 840 = 20 seconds
  • 841 - 950 = 5 seconds
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

ITT Limits (Normal OPs)

A
  • 800 and Below = No Time Limit
  • 801 - 840 = 20 seconds
  • 841 - 950 = Report to Maintenance
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

TQ% Limits (Normal OPs)

A
  • 117.0 and Below = No Time Limit
  • 117.1 - 121.8 = 10 minutes
  • 121.9 - 137.5 = 20 seconds
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Normal T/O

A
  • Time Limit = 5 minutes
  • TQ% = 90
  • ITT = Depends on OAT
  • Np = 101
  • Oil Press = 55 - 65
  • Oil Temp = 0 - 125
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Reserve T/O

A
  • Time Limit = 10 minutes (5 for 2 ENG)
  • TQ% = 100
  • ITT = 800
  • Np = 101
  • Oil Press = 55 - 65
  • Oil Temp = 0 - 125
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Maximum Continuous

A
  • Time Limit = None (Emergency Use)
  • TQ% = 100
  • ITT = 800
  • Np = 101
  • Oil Press = 55 - 65
  • Oil Temp = 0 - 125
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Starting

A
  • Time Limit = 5 seconds
  • ITT = 950
  • Oil Temp = -54
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HOTEL Mode

A
  • ITT = 715
  • Oil Press = 55 - 65
  • Oil Temp = 125
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How Many Starts Allowed

A

3 Starts
1:30 Combined Starter Time
4 minutes OFF after either exceeded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly